Operating the Sensor
44
© SICK AG • Subject to change without notice. • 8017035/ZMO9/2017-06-08
5.5.1
Output Items (OUT1 to OUT3)
When the OUT1, OUT2, or OUT3 tab is selected, you can use the output
display settings to configure the following items.
Setting
item
Bank Setting value/
default value
General description
Out target
Y
Select the area or calculation to set as the output target.
Area1
The measured result of area 1 will be output.
Area2
The measured result of area 2 will be output.
Area3
The measured result of area 3 will be output.
Area4
The measured result of area 4 will be output.
Calc1
The result of calculation 1 will be output.
Calc2
The result of calculation 2 will be output.
Upper limit
Y
Set the upper limit of control output.
-32.766 to +32.767
[
+25.000
]
* The unit varies depending on the measurement function.
* The displayed value includes the “Offset value” setting.
Lower limit
Y
Set the lower limit of control output.
-32.767 to +32.766
[
-25.000
]
* The unit varies depending on the measurement function.
* The displayed value includes the “Offset value” setting.
Out action
Y
Select the operation to perform during output.
Normal
The normal on/off output will be performed.
1shot
Each time that output is turned on, one-shot output will be performed.
OnDelay
When the output is turned on, output will be performed after a delay elapses.
Ready
When trigger input is possible, output will be performed.
Strobe
When the measured value is updated, one-shot output will be performed.
1shot2
When the measurement result exceeds the upper limit or lower limit, the output
will be turned on.
Output turns off (open state) in the trigger standby state.
Out polar
Y
Select the polarity to use for output.
N.O.
When the measurement result exceeds the upper limit or lower limit, the output
will be turned on.
Output turns off (open state) in the trigger standby state.
N.C.
When the measurement result is within the range defined by the upper limit and
lower limit, the output will be turned on. Output turns on (closed state) in the
trigger standby state.
Output
time
Y
Set the output time.
The condition to enable this function is: Out action: 1shot, OnDelay, or Strobe.
0.1 to 204.7
[
0.1
]
[Unit: ms] * You can set this value in steps of 0.1 ms.