Functions
76
© SICK AG • Subject to change without notice. • 8017035/ZMO9/2017-06-08
7.3
Storage Settings
The storage function stores measurement results and profile data to the
Profiler 2.
Stored data can be output via PRO2-Navigator or RS-485 communication.
The "Graph/Calc setting" screen of the Profiler 2 can be used to display
stored measured values as a graph.
7.3.1
Storage
Used to select storage contents.
• OFF: Storage function not used.
• Measure: Stores areas 1 to 4 and calculations 1 and 2 measured val-
ues.
• Profile: Stores profile data and measured values.
No.of Data
Specifies the number of data stored.
The upper limit for storage data depends on the storage target.
• Measured values: Maximum value 65535
• Profile: Maximum value 8000
7.3.2
Start cond
Specifies conditions for starting the storage operation.
• Continue: Storage operation is always performed.
• Hold in: Storage starts when hold input is performed.
• Measure: Storage starts from the instant that the specified area be-
comes measurable.
• Alarm: Storage starts from the instant that the specified area becomes
not measurable.
• UP limit: Storage starts when the measured value of the specified area
exceeds the set threshold.
• LOW limit: Storage starts when the measured value of the specified area
falls below the set threshold.