- 90 -
7-2 Function Code List
–Special Functions / Scheduled Operation Function
Code
No.
Function Name
Data Content
Setting
Resolution
Factory
Presets
User
Setting
Value
1709
Feedback signal disconnection
detection time
0: Only warning
0.01 -119.99 sec.
120: No detection
0.01s
5
1710
Carrier frequency variable by lowering
temperature
(Only when the A mode, function is
enabled.)
0: Disabled 1: Enabled
1
0
1801
Inverter host software version display
Read only
---
Version
1802
Inverter host memory version display
Read only
---
Version
1803
Operation panel software version
display
Read only
---
Version
1804
Operation time display
Read only
1 hour
---
1805
Reading alarm data
0: No function
1: Read start
9: Record erase
1
0
1806
Alarm status confirmation 1
Read only
---
---
1807
Alarm status confirmation 2
Read only
---
---
1808
Alarm status confirmation 3
Read only
---
---
1809
Alarm status confirmation 4
Read only
---
---
1810
Alarm status confirmation 5
Read only
---
---
1811
Serial number display
Read only
---
---
Special functions
1901
Energy-saving mode selection
0: No function
1: Simple energy-saving mode (V/f mode)
2: Auto energy-saving mode
1
0
1902
Simple energy saving rate
0-50%
1%
0
1903
Simple energy saving time
0 -65,000 sec.
1 s
10
2001
V
•
f separation function selection
1: V · f proportional separation
2: Complete separation
1
1
2002
V
•
f separation command voltage
0: Disabled (command is given by VIF1)
0.01-10.00V
0.01V
0
2003
Arbitrary V/f pattern intermediate
voltage 1
0-460V
1V
0
2004
Arbitrary V/f pattern intermediate
voltage 2
0-460V
1V
0
2005
Arbitrary V/f pattern intermediate
frequency 1
0.05-600Hz
0.01Hz
20
2006
Arbitrary V/f pattern intermediate
frequency 2
0.05-600Hz
0.01Hz
40
2007
Auto torque boost selection
0: No auto torque boost
1: Voltage compensation function
2: Slip frequency compensation function
1
0
2008
Slip compensation response time
constant
0-1000
(
set value 1=10ms
)
.
1
10
2009
Slip compensation multiple
0.01-2
0.01
1
Scheduled operation function
2101
1st speed frequency
0-599Hz
0.01Hz
0
2102
2nd speed frequency
0-599Hz
0.01Hz
10
2103
3rd speed frequency
0-599Hz
0.01Hz
20
2104
4th speed frequency
0-599Hz
0.01Hz
30
2105
5th speed frequency
0-599Hz
0.01Hz
40
2106
6th speed frequency
0-599Hz
0.01Hz
50
2107
7th speed frequency
0-599Hz
0.01Hz
60
2108
8th speed frequency
0-599Hz
0.01Hz
0
2109
9th speed frequency
0-599Hz
0.01Hz
0
2110
10th speed frequency
0-599Hz
0.01Hz
5
2111
11th speed frequency
0-599Hz
0.01Hz
15
2112
12th speed frequency
0-599Hz
0.01Hz
25
2113
13th speed frequency
0-599Hz
0.01Hz
35
2114
14th speed frequency
0-599Hz
0.01Hz
45
2115
15th speed frequency
0-599Hz
0.01Hz
55
2116
16th speed frequency
0-599Hz
0.01Hz
0
2201
Selection of scheduled operation
0: Normal operation
1: Simple scheduled operation
2: Disturbed operation
1
0
2202
Simple scheduled operation repetitions
0: Continuous
1-250: Repetition count
1
1
2203
Operation timer T1
0 -65,000 sec.
1s
10
2204
Operation timer T2
0 -65,000 sec.
1s
10
2205
Operation timer T3
0 -65,000 sec.
1s
10