- 13 -
C
h
ap
ter
3
3. Installation
3-1
Installation Location and Storage
This equipment is an electronic control device. Please pay full attention to environment of the device before it is
used.
Caution
Mount the inverter on a metal surface or other non-flammable surface.
Failure to observe this warning may result in a fire.
Do not plug up the air inlet / exhaust hole.
If the air inlet/exhaust is blocked, a fire may be resulted due to internal temperature rise of the device.
Do not place the device near flammable materials.
Failure to observe this warning may result in a fire.
Do not install the device where larger vibration exists.
Otherwise, personal injury may be caused due to falling of the mainframe.
It is absolutely prohibited to store or use the inverter under the environmental conditions
described
below.
Failure to observe this warning may result in a fault, damage, or deterioration, which could lead to fire.
In direct sunlight.
Near a heater or other heat source.
In a location subject to vibration or physical shock.
Near machinery that generates sparks
In a location subject to dust, corrosive or inflammable gases, salt, and water droplets.
Outdoors.
Higher than 2000 meters above sea level.
Other similar environments.
Table 3-1 Work Environment Parameters
Table 3-2 (1) Capacity Modes
Ambient
temperature
Mode A(150% 1min)
-10
℃
-50
℃
Mode B(120% 1min)
-10
℃
-40
℃
Relative
humidity
Below 95%RH
(
no frost
)
Vibration
Below 5.9m/s
2
(0.6G)
Working
environment
Below 2000m above sea level
(When above 1000m, the current will be
reduced for use)
Working
place
Indoor
(free from corrosive and flammable gases,
oil mist, and dust)
Capacity
Mode A
Mode B
0007
0.75kW (150%)
1.5kW (120%)
0015
1.5kW (150%)
2.2kW (120%)
0022
2.2kW (150%)
4.0kW (120%)
※
1
0037
3.7 kW (150%)
5.5kW (120%)
0040
4.0kW (150%)
5.5kW (120%)
0055
5.5kW (150%)
7.5 kW (120%
)
0075
7.5kW (150%)
11kW (120%)
0110
11kW (150%)
15kW (120%)
0150
15kW (150%)
18.5kW (120%)
0185
18.5kW (150%)
22kW (120%)
0220
22kW (150%)
30kW (120%)
0300
30kW (150%)
37kW (120%)
0370
37kW (150%)
45kW (120%)
0450
45kW (150%)
55kW (120%)
0550
55kW (150%)
75kW (120%)
0750
75kW (150%)
90kW (120%)