3-1
Installation Location and Storage
Table 3-2 (2) Capacity Modes
※
1: In 200V series, this is 3.7kW (120%).
Table 3-3 Storage Environment
Storage
temperature
-20
℃
-+65
℃
This temperature is for short periods, such as during transportation.
Ambient temperature must be 30°C or lower for more than 3 months of storage in consideration of
the deterioration of the electrolytic capacitor.
Relative
humidity
Below 95%RH (no frost)
Storage
environment
Places free of direct sunlight, corrosive or inflammable gases, oil mist, dust, steam, water droplet,
vibration, or high salinity.
Table 3-4 Main body mounting screws
200V systems
Capacity
Screws
Recommended Screw Tightening Torque
SVC06-0015
-
2
M4
1.5N•m
(1-1.9N•m)
SVC06-0037
-
2
SVC06-0075
-
2
M5
2.9N•m
(1.6-3.5N•m)
400V systems
Capacity
Screws
Recommended Screw Tightening Torque
SVC06-0007
-
4
M4
1.5N•m
(1-1.9N•m)
SVC06-0015
-
4
SVC06-0022
-
4
SVC06-0037
-
4
SVC06-0055
-
4
M5
2.9N•m
(1.6-3.5N•m)
SVC06-0075
-
4
SVC06-0110
-
4
SVC06-0150
-
4
SVC06-0185
-
4
M5
2.9N•m
(1.6-3.5N•m)
SVC06-0220
-
4
SVC06-0300
-
4
Capacity
Mode A
Mode B
0900
90kW (150%)
110kW (120%)
1100
110kW (150%)
132kW (120%)
1320
132kW (150%)
160kW (120%)
1600
160kW (150%)
200kW (120%)
1850
185kW (150%)
220kW (120%)
2000
200kW (150%)
250kW (120%)
2200
220kW (150%)
280kW (120%)
2500
250kW (150%)
315kW (120%)