7
Emergency control system
(Emergency Lowering)
7-4
RUTHMANN-Steiger
®
TB270
BA.GB.12-27409-05-07-FTA-jr
7.2
Failure of operating staff
The operating staff in the working cage is no longer in a position to carry
out the operational Steiger-movements. Emergency lowering by means of
emergency control. The Steiger-movements are selected by means of the
emergency control from switch box at Steiger-substructure.
Keep ignition switched-on.
Select control stan
d „Emergency Control“.
Open switch box (emergency control) at Steiger-substructure by means
of a key.
Move boom into basic position (
chapter 6.6 ).
Retract jacks (
chapter 6.6 ).
Switch off control stand „Emergency control“.
Lock switch box (emergency control).
Main switch onto position „OFF“.
Содержание 27409
Страница 4: ......
Страница 12: ......
Страница 20: ......
Страница 62: ......
Страница 104: ......
Страница 162: ......
Страница 186: ......
Страница 193: ...9 Maintenance BA GB 12 27409 05 07 FTA jr RUTHMANN Steiger TB270 9 7 9 1 3 Lubricating point plan ...
Страница 211: ...9 Maintenance BA GB 12 27409 05 07 FTA jr RUTHMANN Steiger TB270 9 25 ...
Страница 246: ......
Страница 252: ......
Страница 254: ......
Страница 255: ...13 Spare Parts BA GB 12 27409 05 07 FTA jr RUTHMANN Steiger TB270 13 1 13 Spare Parts ...
Страница 256: ......
Страница 258: ...14 Appendix 14 2 RUTHMANN Steiger TB270 BA GB 12 27409 05 07 FTA jr ...
Страница 260: ......
Страница 261: ...BA GB 12 27409 05 07 FTA jr RUTHMANN Steiger TB270 14 1 ...