MEX DSKY Alpha
— ME
X
DSK
Y
alpha
•
MEX KY BackV
— ME
X
Key
Y
backside
video
•
MEX KY BackA
— ME
X
Key
Y
backside
alpha
•
Aux Bus X
— Aux Bus
X
3.
Use the
Conv. Enable
knob to allow the selected
bus to use SmartConversion (
Yes
), or not (
Off
).
4.
Press
HOME
>
Confirm
.
To Lock a Conversion Loop to a Bus
You can lock a specific conversion loop to a bus. This
dedicates that up/down converter to the selected bus
preventing SmartConversion from using it somewhere
else.
1.
Press
HOME
>
Setup
>
Installation
>
Aux Bus
>
SmartConversion
>
Converter Locking
.
2.
Use the
Aux Bus
knob to select the conversion loop
you want to lock to a bus.
3.
Use the
Lock To Bus/Pair
knob to select the bus,
or bus pair, that you want to lock the selected
conversion loop to.
•
None
— the conversion loop is floating.
•
MEX BKGD+PST
— the conversion loop is
locked to the background and preset buses of the
ME. You should lock two conversion loops to
pair to ensure that there is a conversion loop for
each bus.
•
MEX KeyY
— the conversion loop is locked to
the key bus of the ME.
•
Aux Bus X
— the conversion loop is locked to
the aux bus.
4.
Press
HOME
>
Confirm
.
To Set the Fade to Black Display Mode
The display on the Fade to Black module can display
either the current fade rate or the number of available
up/down converters.
1.
Press
HOME
>
Setup
>
Personality
.
2.
Use the
Option
knob to select
FTB
.
3.
Use the
Value
knob to select whether the display
on the Fade to Black module shows the fade to black
transition rate (
FTB
), or the number of available
conversion loops (
SmrtConv
).
86