Auxiliary Control Panels
An auxiliary control panel provides an extra row of
source buttons that can be assigned to an aux bus. This
single row of buttons can be used to select sources on
the aux output, or to visually follow what is selected on
an aux bus.
The switcher supports the V-053B, the V-159 series, and
AP-AUX2RU series of auxiliary control panels.
AP-AUX2RU Series Auxiliary Control
Panels
The V-159 series and AP-AUX2RU series of auxiliary
control panels are available in various sizes to match the
number of source buttons on your control panel. The
panels can be installed either on the back of the control
panel or into the desk. The V-159 auxiliary control panel
can also be installed into a 19-inch rack frame.
To Assign an AP-AUX2RU Series Auxiliary
Control Panel to a Panel Row
Refer to the documentation than came with your auxiliary
control panel for information on cabling and physically
connecting it to the switcher.
1.
Press
HOME
>
Setup
>
More
>
Panel Modules
.
2.
Press
Yes
.
3.
Press
Quick Configuration
.
4.
Press
Internal Rows
or
External Rows
to assign
the auxiliary control panel to an internal or external
panel row.
•
Internal Rows
— if you need menu follows
and double press actions. Actions such as
double-pressing a crosspoint button to assign a
color corrector to that video source must be done
on an internal panel row.
•
External Rows
— if you do not need menu
follows or double press action.
5.
Press the
Start Row X
button for the row that you
want to start assigning modules to.
If you are using internal panel rows, it is
recommended that you select a row that is not used
on the control panel (row 5, for example) so that the
module assignment for the control panel is not
affected.
6.
Starting on the far left side, press a button on each
module on the auxiliary control panel.
7.
Press
Exit
.
8.
Press
HOME
>
Confirm
.
V-053B Auxiliary Control Panels
The V-053B auxiliary control panel must be set up on
one of the External Link ports on the back of the control
panel. This includes the range of aux buses that you want
to make available to all the V-053B auxiliary control
panels connected to that port. You can daisy-chain a
number of panels together.
To Set Up a V-053B Auxiliary Control Panel
Refer to the documentation that came with the V-053B
for information on cabling and power connections.
1.
Press
HOME
>
Setup
>
Installation
>
Com
Setup
>
Type
.
2.
Use the
Com Port
knob to select the
ExtLnk X
port that the auxiliary control panel is connected to.
3.
Use the
Device
knob to select
Remote Aux
.
4.
Use the
Aux Buses
knob to select the range of aux
buses that you want to make available to the remote
aux panels connected to the selected port.
5.
Press
HOME
>
Confirm
.
To Assign an Aux Bus to a V-053B Auxiliary
Control Panel
1.
Press
HOME
>
Setup
>
Installation
>
Aux Bus
>
Remote Panels
>
Remote Panel Setup
.
This places all the V-053B panels connected to the
switcher into programming mode. The On-Air
indicators on the panels flash.
2.
Press the source buttons that correspond to the aux
buses you want to assign to the auxiliary control
panel. Each auxiliary control panel can be assigned
to one or all aux buses. Press the button repeatedly
to assign a different mode to that aux bus on the
panel.
•
Off
— the aux bus is not assigned to the auxiliary
control panel.
•
On
— the aux bus is assigned to the auxiliary
control panel, allowing you full control to select
sources on the aux bus.
•
Flashing
— the aux bus is assigned to the
auxiliary control panel, allowing you to only
view what is being selected on the aux bus. You
will not be able to change the source selections
for this aux bus from this auxiliary control panel.
Starting from the top left, the first 12 source buttons
on the control panel correspond to the 12 aux buses
that were assigned to the External Link port. For
example, if aux buses 1:1 to 2:4 were assigned to
Acuity Setup Manual (v9.2) — Auxiliary Control Panels •
71