Note:
Factory Default will not change the reference or video
format. The reference and video format remain the same as
they were before the factory default.
•
Custom Controls
— all the custom controls that
are stored on the switcher. Bank setting are stored in
the Installation setup.
•
Default VTR Clips
— all VTR and video server
timecode and clip information on the switcher.
•
Default NV-RAM
— all the information stored in
the NV-RAM. Non-Volatile RAM on the switcher
contains information such as active key effects and
some personality settings.
•
Default DVE Sequences
— all the sequences that
have been stored on the switcher.
•
Default Bus Maps
— all the bus maps on the
switcher.
•
Default Shot Box Pages
— all the Shot Box pages
that have been stored on the switcher.
•
Camera File
— all the stored shots for cameras that
do not store shots on the camera itself.
•
CC/Macro Attachments
— all the mappings of
custom controls that are attached to buttons.
•
Default MultiViewer
— all the layouts and assigned
sources for the MultiViewer that have been stored on
the switcher. The assignment of a MultiViewer to
output BNCs is stored in the
Installation
register, as
well as all the mapping of what layout is assigned to
each MultiViewer.
•
Default CC Variables
— all custom control
variables.
To Recall Default Settings
1.
Press
HOME
>
Setup
>
Installation
>
More
>
More
>
Recall Factory
.
2.
Press the button for the register you want to default
or press
Factory Reset All
to recall all factory
default setting.
3.
Press
HOME
>
Confirm
.
Frame Over-Temperature Shutdown
In the event that the frame over-heats, the switcher can
be set to shutdown boards to prevent damage. When the
frame over-heats, a warning is provided with the option
to over-ride the shutdown. If you do not cancel the
shutdown in 15 minutes, the frame will shutdown the
boards automatically.
Frame over-heating can be caused by a high ambient
temperature in the equipment rack room, poor airflow
through the frame fan filter, or failing frame or power
supply fans.
After the frame has shutdown the boards, you must
correct the conditions that caused the over-heating and
restart the frame.
To Set the Frame Over-Temperature Shutdown
Mode
1.
Press
HOME
>
Setup
>
Installation
>
More
>
More
>
Temperature Alarm
.
2.
Press
Shutdown
to toggle the over-temperature
shutdown
On
or
Off
.
•
On
— the switcher shuts down all the frame
boards, except the Frame CPU, when the frame
is over-heating
•
Off
— the switcher does not shut down boards
when the frame is over-heating.
3.
Press
Yes
to confirm the new settings.
Locking Menus
You can lock both the Installation and Personality menus.
Locking a menu makes it so that a password is required
to make changes to the menus, or recall the installation
or personality register.
To Lock a Menu
The same procedure is used to unlock a menu that has
already been locked.
1.
Navigate to the lock menu for the menu you want
to lock.
•
Installation
— Press
HOME
>
Setup
>
More
>
Lock/Unlock Installation
.
•
Personality
— Press
HOME
>
Setup
>
More
>
Lock/Unlock Personality
.
2.
Press
Installation Lock
or
Personality Lock
to
select whether the menus are locked (
On
), or
unlocked (
Off
).
Tip:
Press Clear Password to delete the current password
that is used to lock the menu.
3.
Press
Add/Change Password
.
4.
Enter the new password in the
New Password
field.
5.
Press
Accept New Password
.
6.
Press
HOME
>
Confirm
.
Power Supply Replacement
The power supplies in both the control panel and frame
are designed to be easily replaced. The power supplies
in the frame can be removed with the frame powered on,
106
• Switcher Maintenance — Acuity Setup Manual (v9.2)