![Ross Acuity 4410AR-020 Скачать руководство пользователя страница 43](http://html1.mh-extra.com/html/ross/acuity-4410ar-020/acuity-4410ar-020_setup-manual_1489003043.webp)
•
Off
— Bus Hold feature not cleared when a software
reset is performed.
•
On
— Bus Hold feature cleared on every bus when
a software reset is performed.
DD Key Delegation
Sets how the keys on the key bus of a Double-Down
panel are configured.
Press
HOME
>
Setup
>
Personality
and use the
Option
knob to select
DD Key Delegation
.
•
Even On Top
— Even numbered keyers (2,4,6,8)
are on the top row and odd numbered keyers (1,3,5,7)
on the bottom row of the key bus.
•
Odd On Top
— Odd numbered keyers (1,3,5,7) are
on the top row and even numbered keyers (2,4,6,8)
on the bottom row of the key bus.
•
On Top
— The top row of the key bus follows the
key selection and the bottom row must be set
manually.
•
On Bottom
— The bottom row of the key bus
follows the key selection and the top row must be set
manually.
Default Trans Active
Allows you to set a default transition rate for switcher
transitions, effects, and sequences.
Press
HOME
>
Setup
>
Personality
and use the
Option
knob to select
Default Trans Active
.
•
Off
— use the video format based default transition
rates when you default an ME or the entire switcher.
•
On
— use the selected default transition rates when
you default an ME or the entire switcher.
Default Trans Eff Rate
Allows you to set a default effects dissolve rate.
Press
HOME
>
Setup
>
Personality
and use the
Option
knob to select
Default Trans Eff Rate
.
Note:
This rate is only used if the Default Trans Activefeature
is on.
•
Use the
Rate
knob to set a default rate, in frames.
Default Trans FTB Rate
Allows you to set a default fade to black rate.
Press
HOME
>
Setup
>
Personality
and use the
Option
knob to select
Default Trans FTB
.
Note:
This rate is only used if the Default Trans Activefeature
is on.
•
Use the
Rate
knob to set a default rate, in frames.
Default Trans Key Rate
Allows you to set a default keyer transition rate.
Press
HOME
>
Setup
>
Personality
and use the
Option
knob to select
Default Trans Key Rate
.
Note:
This rate is only used if the Default Trans Activefeature
is on.
•
Use the
Rate
knob to set a default rate, in frames.
Default Trans ME Rate
Allows you to set a default ME transition rate.
Press
HOME
>
Setup
>
Personality
and use the
Option
knob to select
Default Trans ME
.
Note:
This rate is only used if the Default Trans Activefeature
is on.
•
Use the
Rate
knob to set a default rate, in frames.
Default Sequence Rate
Allows you to set a default sequence rate.
Press
HOME
>
Setup
>
Personality
and use the
Option
knob to select
Dflt Trns Seq
.
Note:
This rate is only used if the Default Trans Activefeature
is on.
•
Use the
Rate
knob to set a default rate, in frames. If
you set the rate to 1, the sequence uses the duration
set in the sequence.
Double Press Rate
Sets the length of time that you have to press a button a
second time in order for the switcher to treat it as a
double-press.
Press
HOME
>
Setup
>
Personality
and use the
Option
knob to select
Double Press Rate
.
•
Use the
Value
knob to select the amount of time, in
frames, that you are given to press a button again for
the switcher treat it as a double-press.
DSK Auto Cut
Sets whether or not the DSKs are cut off-air when a
source is selected directly on the main Program Bus of
the switcher.
Press
HOME
>
Setup
>
Personality
and use the
Option
knob to select
DSK X Auto Cut
.
•
Off
— DSK not affected by selections made directly
on the Program Bus of the Program/Preset ME.
•
On
— DSK automatically taken off-air when any
source is selected directly on the Program Bus of the
Program/Preset ME.
Acuity Setup Manual (v9.2) — Personality •