![Rohde & Schwarz EX-IQ-BOX Скачать руководство пользователя страница 298](http://html1.mh-extra.com/html/rohde-and-schwarz/ex-iq-box/ex-iq-box_user-manual_1477982298.webp)
Remote Control Commands
R&S
®
EX-IQ-BOX
283
User Manual 1409.5570.32 ─ 05
Manual operation:
See
[:SOURce<hw>]:EBOX:USER:TRIGger:STATe?
Queries the trigger status.
Return values:
<State>
STOP | RUN
Example:
EBOX:USER:TRIG:STAT?
Response:
STOP
, i.e. triggering is stopped.
Usage:
Query only
Manual operation:
See
9.3.9 SSI Subsystem
The
USER:SSI
subsystem contains the commands for configuring the signal transmis-
sion for SSI (serial synchronous interface) signals.
............................................................283
.......................................................................284
.............................................................284
...............................................................284
.......................................................................284
...........................................................................284
...............................................285
......................................................285
...............................................................285
...............................................................285
................................................................286
.................................................................286
[:SOURce<hw>]:EBOX:USER:SSI:CMData:RX|TX
<CMData>
In transmitter mode, the command defines the number of the C&M bit word as defined in
the size parameter, see
. In receiver
mode, you can query the number.
Parameters:
<CMData>
string
Range:
0 to 32
Increment: 1
Example:
EBOX:USER:SSI:CMSIZE "8"
sets the word size to eight bit.
EBOX:USER:SSI:CMD:TX "#HA5,8"
EBOX:USER:SSI:CMD:RX?
Manual operation:
See
User Defined - Remote Control Commands
Содержание EX-IQ-BOX
Страница 147: ...Protocol Settings R S EX IQ BOX 132 User Manual 1409 5570 32 05 CPRI...