![Rohde & Schwarz EX-IQ-BOX Скачать руководство пользователя страница 292](http://html1.mh-extra.com/html/rohde-and-schwarz/ex-iq-box/ex-iq-box_user-manual_1477982292.webp)
Remote Control Commands
R&S
®
EX-IQ-BOX
277
User Manual 1409.5570.32 ─ 05
Parameters:
<Stype>
IQ | IF
IQ
Transmits the digital I and Q signals separately.
*RST:
IQ
Example:
SOUR1:EBOX:USER:DATA:STYP?
queries the set signal type.
Manual operation:
See
[:SOURce]:BBIN:EXTernal:DATA:TYPE
<Type>
[:SOURce<hw>]:IQ:OUTPut:EXTernal:DATA:TYPE
<Type>
SOURce:TRANsmitter:DATA:TYPe
SOURce:RECeiver:DATA:TYPe
[:SOURce<hw>]:EBOX:USER:DATA:TYPE
<Type>
Selects the signal data type.
Data type "PFSamples" is intended for future use.
Parameters:
<Type>
SAMPles | PFSamples
SAMPles
Sets signal type to samples.
*RST:
SAMPles
Example:
EBOX:USER:DATA:TYPE?
queries the set data type.
9.3.7 Test Subsystem
The
USER:TEST
subsystem provides commands for testing the user interface between
the R&S
EX-IQ-BOX and the DUT.
.................................................................277
...............................................................278
...............................................................278
............................................................279
...............................................................279
..................................................280
................................................281
................................................................281
[:SOURce<hw>]:EBOX:USER:TEST:RX:BER?
Queries the bit error rate. The function consecutively counts the number of discrepancies
that occur during the test. The BER result is the ratio, which is calculated by dividing the
number of error bits by the total number of bits.
User Defined - Remote Control Commands
Содержание EX-IQ-BOX
Страница 147: ...Protocol Settings R S EX IQ BOX 132 User Manual 1409 5570 32 05 CPRI...
Страница 391: ......