![Rohde & Schwarz EX-IQ-BOX Скачать руководство пользователя страница 114](http://html1.mh-extra.com/html/rohde-and-schwarz/ex-iq-box/ex-iq-box_user-manual_1477982114.webp)
Protocol Settings
R&S
®
EX-IQ-BOX
99
User Manual 1409.5570.32 ─ 05
State
Activate signal transmission.
This function applies to R&S
DigIConf, since R&S signal generators and analyzers start
signal transmission directly in the instrument.
Note:
Data transmission requires that the respective breakout board is connected.
Remote command:
Logic Type
Selects the digital signaling system used for transmitting the baseband signal from or to
the DUT.
Note: SCPI notation varies
The SCPI notation varies, when you remotely control the R&S
EX-IQ-BOX on R&S
EX-
IQ-BOX or R&S signal generators and R&S signal analyzers.
Follow the command link below for description of the command and its syntax in detail.
"LVDS"
The signal is transmitted by using the signaling system LVDS (
L
ow
V
oltage
D
ifferential
S
ignaling).
"LVTTL"
The signal is transmitted by using LVTTL technology (
L
ow
V
oltage
T
ransistor
T
ransistor
L
ogic) with a voltage level of 3.3
V.
"x.x V CMOS"
The signal is transmitted by using the CMOS Technology (
C
omple-
mentary
M
etal
O
xid
S
emiconductor). x.x represents the voltage level
provided in the list.
"x.x V SSI"
The signal is transmitted by using the SSI Technology (
S
erial
S
ynch-
ronuos
I
nterface). Voltage levels are 1.5
V and 1.8
V.
Remote command:
Direction
Selects the direction of signal transmission from the DUT to R&S
EX-IQ-BOX or vice
versa.
Note:
Setting the transmission path and starting depend on the activating device
●
R&S
DigIConf
Signal direction is selected in the "Direction" field of the R&S
EX-IQ-BOX "User
Defined" settings dialog. Select "Transmitter/Receiver" in the drop down list.
The transmission is activated by switching On the "State" button.
●
R&S signal analyzers
Signal direction is selected in the "Select Type" field of the "EXIQ-Box Settings" dia-
log. Select "Transmitter/Receiver" in the drop down list, as described in
To toggle between the different types, press the "TX SETTINGS" or "RX SET-
TINGS" softkey to select the type from the combo box.
●
R&S signal generators
The direction of signal transmission is distinguished as input and output settings dia-
logs "EX-IQ-BOX BBIN" and "EX-IQ-BOX BBOUT". Therefore, "Direction" is not
required in control by for R&S signal generators.
User Defined
Содержание EX-IQ-BOX