![Rohde & Schwarz EX-IQ-BOX Скачать руководство пользователя страница 276](http://html1.mh-extra.com/html/rohde-and-schwarz/ex-iq-box/ex-iq-box_user-manual_1477982276.webp)
Remote Control Commands
R&S
®
EX-IQ-BOX
261
User Manual 1409.5570.32 ─ 05
Example:
SOUR:TRAN:SEND
The connected R&S
EX-IQ-BOX receives data from an R&S signal
analyzer and transmits this data to the DUT.
Manual operation:
See
[:SOURce<hw>]:EBOX:USER:STATe
<State>
Activates signal transmission.
This function applies to R&S
DigIConf, since R&S signal generators and analyzers start
signal transmission directly in the instrument.
Note:
Data transmission requires that the respective breakout board is connected.
Parameters:
<State>
OFF | ON
*RST:
OFF
Example:
EBOX:USER:STAT ON
switch on signal data transmission.
Manual operation:
See
9.3.3 Settings Subsystem
The
USER:SETTings
subsystem contains the commands for loading and storing appli-
cation settings in files.
............................................................261
................................................................262
..................................................................262
................................................................262
[:SOURce<hw>]:EBOX:USER:SETTing:CATalog?
Queries the available settings files in the specified directory. Settings files are used to
store current application settings. Only files with the file extension
*.iqbox
will be listed.
Access to the files via remote is possible using the commands of the
MEMM
subsystem.
Return values:
<Catalog>
string
String parameter to select the directory where settings files are
stored.
Example:
MEMM:CDIR "d:\DigIConf\Settings\User"
Set the default directory and path to
d:\DigIConf\Settings\User
.
SOUR1:EBOX:USER:SETT:CAT?
read out all settings files of the
DigIConf\Settings\User
directory on drive
d:
User Defined - Remote Control Commands