3.3.1.2
EC control
Enable EC control
Day EC setpoint
Night EC setpoint
Max. calc. EC setp. /alarm
Min. alarm zone of control EC
Max. alarm zone of control EC
Max. difference of monitor EC
Maximum fresh water EC
Alarm delay of control EC
Alarm delay of monitor EC
Al. delay of fresh water EC
Start of rad. influence on EC
End of rad. influence on EC
Max. rad. influence on EC
Ratio of dosage valve 1 - 8
Moving average active
Moving average time
EC control with pre-meas.
EC differentiation time
Max. control perc. EC
Max. rad. influence on EC
Gain
Integration time
Path: Settings>Programs>Program name>EC control
Enable EC control
No: Not active.
Yes: Active.
Day EC setpoint 0 - 9.9 mS/cm
The desired EC value of the irrigation water, expressed in milli-Siemens per
centimetre.
This EC value applies to all valves in the relevant valve group.
Night EC setpoint 0 - 9.9 mS/cm
The desired EC value of the irrigation water, expressed in milli-Siemens per
centimetre.
This EC value applies to all valves in the relevant valve group.
Max. calc. EC setp. /alarm 0 - 9.9 mS/cm
If the calculated control EC exceeds this value, an alarm will be triggered.
This safeguard only works if the EC pre-measurement is active.