Current system pump
Manually select the current system pump. If 'Automatic' is selected, the controller will
switch to the other pump at midnight.
If desired, you can select a different pump for the remainder of the day.
Off delay of pumps
The delay time between the end of an irrigation cycle and the deactivation of the
system pumps.
Delay of external contact
The duration that the external contact must transmit a signal, in order for the
controller to accept this signal.
Drain water meter
Select the type of flow rate meter that is present for measuring the volume of drain
water.
None: No flow rate meter is present.
Water meter: A water meter with pulse contact is present.
Flow meter: A flow rate meter (e.g. GF15) is present.
Flow factor of drain water meter 0 - 200
Flow rate meter: The K-factor of the flow rate sensor in pulses/litres.
Water meter: The flow rate factor of the litre counter in litres/pulses.
3.3.2.1
Registration
Registration reset time
Reset water consumption
Path: Settings>General>Registration
Registration reset time
The time at which the registration data (such as the water consumption per day) will
be reset to zero.
This is a shared setting, which means that it applies to all valve groups.
Real time: Fixed time point in time.
Sunrise: time before (-) or after sunrise.
Sunset: time before (-) or after sunset.
Reset water consumption by period
Select the desired option for resetting the water consumption to zero.
This is a shared setting, which means that it applies to all valve groups.
Aqua CX300
57
Содержание Aqua CX300
Страница 1: ...SV 02 03 2020 96010102 User Manual Aqua CX300...