Flow rate 0 & 1000
The measured flow rate of the water being supplied to the valve or valve group in
question, expressed in litres per minute.
4.14
EC control activities
Pre-set setpoint
Calculated setpoint
Pre-blending EC setpoint
Measured control EC
Measured monitor EC
Measured pre-measurement EC
Measured pre-blending EC
Control temperature
Monitor temperature
Pre-measurement temperature
Pre-blending temperature
Control value 1 - Control value 8 (%)
Pre-blending control value
Path: Display summaries>EC control activities
Pre-set setpoint 0 - 10 ms cm
The EC setpoint (or target value) that has been entered into the system. This is the
value before it has been corrected by the pre-set influences.
Calculated EC setpoint 0 - 10 mS/cm
The EC setpoint calculated by the controller. This is the value after it has been
corrected by the pre-set influences. This is the actual target value that the controller
will aim to reach.
Pre-blending EC setpoint 0 - 10 mS/cm
The EC setpoint calculated by the controller. This value is used to control the ratio of
fresh water to drain water, which is is supplied to the irrigation unit.
Measured control EC in 0 - 10 mS/cm
The EC setpoint that has been entered into the system. This is the value before it has
been corrected by the pre-set influences.
Measured monitor EC 0 - 10 mS/cm
The EC value measured by the monitor sensor.
Measured pre-measurement EC in 0 - 10 mS/cm
The EC value measured by the pre-measurement EC sensor.
Measured pre-blending EC 0 - 10 mS/cm
The EC value measured by pre-blending EC sensor.
Aqua CX300
74