Depending on the option selected for 'Response to EC/pH alarm', the program will
either be paused or irrigation will continue with fresh water.
Check:
the measured EC value (control, monitor or pre-blending EC) and compare this
value with the calculated EC setpoint.
the pre-set EC setpoint.
the 'Minimum EC zone' or the 'Maximum EC zone' are set too low.
the Radiation influence on the EC value.
the influence of the EC value of the supply water.
whether the correct recipe has been selected, and the dosage ratio is set
correctly.
whether the EC sensor is dirty and needs cleaning.
Pre-mixing EC too high, group has been paused
The measured EC value (control, monitor or pre-blending EC) is too high.
Depending on the option selected for 'Response to EC/pH alarm', the program will
either be paused or irrigation will continue with fresh water.
Check:
the measured EC value (control, monitor or pre-blending EC) and compare this
value with the calculated EC setpoint.
the pre-set EC setpoint.
the 'Minimum EC zone' or the 'Maximum EC zone' are set too low.
the Radiation influence on the EC value.
the influence of the EC value of the supply water.
whether the correct recipe has been selected, and the dosage ratio is set
correctly.
whether the EC sensor is dirty and needs cleaning.
Pre-mixing EC too low, group has continued
The EC value (control, monitor or pre-blending EC) is too low.
Depending on the option selected for 'Response to EC/pH alarm', the program will
either be paused or irrigation will continue with fresh water.
Check:
the measured EC value (control, monitor or pre-blending EC) and compare this
value with the calculated EC setpoint.
the pre-set EC setpoint.
the 'Minimum EC zone' or the 'Maximum EC zone' are set too low.
the Radiation influence on the EC value.
the influence of the EC value of the supply water.
whether the correct recipe has been selected, and the dosage ratio is set
correctly.
whether the EC sensor is dirty and needs cleaning.
Pre-mixing EC too low, group has been paused
The measured EC value (control, monitor or pre-blending EC) is too low.