External EC/pH control
No: External EC/pH control will remain enabled during pre-rinsing or post-rinsing of
the crop.
Yes: External EC/pH control will be disabled during pre-rinsing or post-rinsing of the
crop.
Flow rate alarm
The valve group will be paused if a valve in that group is skipped because the flow
rate was too low or too high.
Options:
Pause button
Stop
Pause & Start
Pause & Alarm
Pause & Restart & Alarm
Skip valve & Alarm
Response to external contact
The action to be taken by the program when an external contact is detected:
Not active: Continue irrigation.
Pause: Pause the program.
Stop: Stop the program.
Pause & start: Pause the program. Continue irrigation when the external contact
is no longer detected.
Alarm: The alarm is enabled. This function may be combined with any of the
above functions.
Skip valve: Skip the valve (or valves) supplying water at that moment.
Stir fertilizer tank
Select whether the fertilizers should be stirred before and during irrigation.
No: Not active.
Yes: Active.
Irrigation by…
Select whether you want to program and display irrigation by valve group of by valve.
Group: program and display irrigation and crop pre-rinsing / post-rinsing by
valve group.
Valve: program and display irrigation and crop pre-rinsing / post-rinsing by
valve.
Open valve delay
The delay time between the activation of the system pump and the opening of the
valve.
Aqua CX300
44