the pre-set pH setpoint
whether the 'Minimum pH zone' is set too low.
Fresh water pH too high, group paused
The measured pH value (control or monitor pH) is too high.
Depending on the option selected for 'Response to EC/pH alarm', the program will
either be paused or irrigation will continue with fresh water.
Check:
the measured pH value (control or monitor pH) and compare this value with the
calculated pH setpoint.
the pre-set pH setpoint
whether the 'Maximum pH zone' is set too low.
Fresh water pH too high, group continued
The measured pH value (control or monitor pH) is too high.
Depending on the option selected for 'Response to EC/pH alarm', the program will
either be paused or irrigation will continue with fresh water.
Check:
the measured pH value (control or monitor pH) and compare this value with the
calculated pH setpoint.
the pre-set pH setpoint
whether the 'Maximum pH zone' is set too low.
Alarm of control pH sensor, group paused
The value measured by the sensor is outside the measurement range.
Check the sensor.
Contact your installer.
Alarm of monitor pH sensor, group paused
The value measured by the sensor is outside the measurement range.
Check the sensor.
Contact your installer.
Alarm of external pH control, group paused
External pH control has triggered an alarm. As a result, pH control has stopped and
the valve group has been paused.
The valve group will only resume after you initiate a manual start. The fogging
program will, however, continue.
Check pH control.
Aqua CX300