3.3 ADJUSTING THE FOCUS (MTF ADJUSTMENT)
Purpose: To adjust the focus distance between the CCD and the lens.
Ajustment Standard: a
−
b
a
+
b
x 100
≥
60 %
1. Position the resolution chart so that the 200 dpi area on the test chart can
be read.
2. Press the Print Start key to turn on the fluorescent lamp.
3. Check if the waveform looks like the one you see in the illustration above.
4. If it does not, loosen the Allen screw [A] and adjust the position of the
lens [B] by moving it as shown by the arrow.
5. After the adjustment, retighten the Allen screw [A].
[A]
[B]
RESOLUTION
CHART 200DPI
a
−
b
a
+
b
x 100
≥
60%
a
b
1 December 1993
5-12
Содержание VT3500
Страница 8: ...2 6 USER CODE MODE 4 27 2 6 1 User Codes 4 27 2 6 2 How To Use a User Code 4 27...
Страница 15: ...SECTION 1 OVERALL MACHINE INFORMATION...
Страница 19: ...2 GUIDETOCOMPONENTSANDTHEIRFUNCTION 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 1 December 1993 1 5...
Страница 21: ...16 17 18 19 20 21 22 23 24 25 26 27 28 1 December 1993 1 7...
Страница 37: ...SECTION 2 SECTIONAL DESCRIPTION...
Страница 89: ...E H D G F D C A B C I J K 1 December 1993 2 53...
Страница 123: ...1 December 1993 2 87...
Страница 127: ...1 December 1993 2 91...
Страница 161: ...Background Patterns The 40 background patterns shown below can be selected 1 2 3 4 5 6 7 8 9 1 December 1993 2 125...
Страница 162: ...13 14 15 16 17 18 10 11 12 1 December 1993 2 126...
Страница 163: ...19 20 21 22 23 24 25 26 27 1 December 1993 2 127...
Страница 164: ...28 29 30 31 32 33 34 35 36 1 December 1993 2 128...
Страница 165: ...37 38 39 40 1 December 1993 2 129...
Страница 192: ...SECTION 3 INSTALLATION...
Страница 206: ...SECTION 4 SERVICE TABLES...
Страница 209: ...Q Fig 4 R S Fig 5 T U Fig 6 V Fig 7 1 December 1993 4 3...
Страница 234: ...SECTION 5 REPLACEMENT AND ADJUSTMENT...
Страница 317: ...SECTION 6 TROUBLESHOOTING...