5501
[PM Alarm]
*CTL -
001 PM Alarm Level
[0 to 9999 / 0 / 1 /step]
0: Alarm off
1 to 9999: Alarm goes off when Value (1 to 9999) x 1000
≥
PM counter
002 Original Count Alarm
[0 or 1 / 1 / – ]
0: No alarm sounds
1: Alarm sounds after the number of originals passing
through the ARDF
≥
10,000
5413
[Lockout Setting]
001 Lockout On/Off
*CTL
Switches on/off the lock on the local address book
account.
[0 to 1/0/1]
0: Off, 1: On
002 Lockout Threshold
*CTL
Sets a limit on the frequency of lockouts for account
lockouts.
[1 to 10/5/1]
003 Cancellation On/Off
*CTL
Determines whether the system waits the prescribed
time for input of a correct user ID and password
after an account lockout has occurred.
[0 to 1/0/1]
0: Off (no wait time, lockout not cancelled)
1: On (system waits, cancels lockout if correct user
ID and password are entered.
004 Cancellation Time
*CTL
Determines the length of time that the system waits
for correct input of the user ID and password after
a lockout has occurred. This setting is used only if
SP5413-3 is set to "1" (on).
[1 to 999/60/1 min.]
5414
[Access Mitigation]
System Service Mode
321
8
Содержание MPC 2800 AT-C2
Страница 1: ...Model AT C2 Machine Code D023 D025 Field Service Manual July 2008 Subject to change...
Страница 2: ......
Страница 16: ...Overview Component Layout 1 Product Information 14 1...
Страница 125: ...6 Attach the on standby decal O to the right hand side of the main power switch Anti Condensation Heater Type A 123 2...
Страница 152: ...2 Installation 150 2...
Страница 156: ...3 Preventive Maintenance 154 3...
Страница 171: ...Left Cover 1 Left cover A x 6 Rear Cover 1 Rear cover A x 8 Exterior Covers 169 4...
Страница 176: ...3 Ozone filters A in the right top cover 4 Replacement and Adjustment 174 4...
Страница 243: ...3 Toner transport motor A x 3 x 1 Toner Collection Unit 1 Gear Unit p 228 Drive Unit 241 4...
Страница 249: ...6 Development clutch K A x 1 Drive Unit 247 4...
Страница 265: ...8 Thermopile F x 2 x 1 Fusing 263 4...
Страница 272: ...3 Open the duplex door A 4 Right door cover B x 4 5 Right door rear cover A x 3 4 Replacement and Adjustment 270 4...
Страница 286: ...Behind the IOB FCU and G3 Interface Unit F BICU G Controller Board H HDD 4 Replacement and Adjustment 284 4...
Страница 287: ...Controller Box Open I ITB Power Supply Board Electrical Components 285 4...
Страница 327: ...Controller Self Diagnostics 325 5...
Страница 347: ...6 Troubleshooting Service Call Conditions See Appendices for the following information SC Tables 345 6...
Страница 354: ...MEMO 352...
Страница 355: ...Model AT C2 Machine Code D023 D025 Appendices July 2008 Subject to change...
Страница 356: ......
Страница 359: ...SP1 xxx System and Others 496 SP2 XXX Scanning image quality 496 3...
Страница 360: ...4...
Страница 396: ...2 Appendix Maintenance Tables 40 2...
Страница 474: ...4 Appendix Process Control Error Conditions 118 4...
Страница 476: ...5 Appendix Troubleshooting Guide 120 5...
Страница 484: ...5 Appendix Troubleshooting Guide 128 5...
Страница 492: ...Sensor Locations 6 Appendix Jam Detection 136 6...
Страница 500: ...7 Appendix Electrical Component Defects 144 7...
Страница 854: ...MEMO 498...
Страница 855: ...MEMO 499...
Страница 856: ...MEMO 500 EN...