• Refer to the Service Tables for the range of allowed settings.
1. Do this procedure to enter a setting:
• Press
to toggle between plus and minus and use the keypad to enter the appropriate number.
The number you enter writes over the previous setting.
• Press
to enter the setting. (The value is not registered if you enter a number that is out of
range.)
• Press “Yes” when you are prompted to complete the selection.
2. If you need to perform a test print, press Copy Window to open the copy window and select the
settings for the test print. Press Start
and then press SP Mode (highlighted) in the copy window to
return to the SP mode display.
3. Press Exit two times to return to the copy window when you are finished.
Exiting Service Mode
Press the Exit key on the touch-panel.
Service Mode Lock/Unlock
At locations where the machine contains sensitive data, the customer engineer cannot operate the machine
until the Administrator turns the service mode lock off. This function makes sure that work on the machine is
always done with the permission of the Administrator.
1. If you cannot go into the SP mode, ask the Administrator to log in with the User Tool and then set
“Service Mode Lock” to OFF after he or she logs in:
User Tools > System Settings > Administrator Tools > Service Mode Lock > OFF
• This unlocks the machine and lets you get access to all the SP codes.
5. System Maintenance Reference
304
5
Содержание MPC 2800 AT-C2
Страница 1: ...Model AT C2 Machine Code D023 D025 Field Service Manual July 2008 Subject to change...
Страница 2: ......
Страница 16: ...Overview Component Layout 1 Product Information 14 1...
Страница 125: ...6 Attach the on standby decal O to the right hand side of the main power switch Anti Condensation Heater Type A 123 2...
Страница 152: ...2 Installation 150 2...
Страница 156: ...3 Preventive Maintenance 154 3...
Страница 171: ...Left Cover 1 Left cover A x 6 Rear Cover 1 Rear cover A x 8 Exterior Covers 169 4...
Страница 176: ...3 Ozone filters A in the right top cover 4 Replacement and Adjustment 174 4...
Страница 243: ...3 Toner transport motor A x 3 x 1 Toner Collection Unit 1 Gear Unit p 228 Drive Unit 241 4...
Страница 249: ...6 Development clutch K A x 1 Drive Unit 247 4...
Страница 265: ...8 Thermopile F x 2 x 1 Fusing 263 4...
Страница 272: ...3 Open the duplex door A 4 Right door cover B x 4 5 Right door rear cover A x 3 4 Replacement and Adjustment 270 4...
Страница 286: ...Behind the IOB FCU and G3 Interface Unit F BICU G Controller Board H HDD 4 Replacement and Adjustment 284 4...
Страница 287: ...Controller Box Open I ITB Power Supply Board Electrical Components 285 4...
Страница 327: ...Controller Self Diagnostics 325 5...
Страница 347: ...6 Troubleshooting Service Call Conditions See Appendices for the following information SC Tables 345 6...
Страница 354: ...MEMO 352...
Страница 355: ...Model AT C2 Machine Code D023 D025 Appendices July 2008 Subject to change...
Страница 356: ......
Страница 359: ...SP1 xxx System and Others 496 SP2 XXX Scanning image quality 496 3...
Страница 360: ...4...
Страница 396: ...2 Appendix Maintenance Tables 40 2...
Страница 474: ...4 Appendix Process Control Error Conditions 118 4...
Страница 476: ...5 Appendix Troubleshooting Guide 120 5...
Страница 484: ...5 Appendix Troubleshooting Guide 128 5...
Страница 492: ...Sensor Locations 6 Appendix Jam Detection 136 6...
Страница 500: ...7 Appendix Electrical Component Defects 144 7...
Страница 854: ...MEMO 498...
Страница 855: ...MEMO 499...
Страница 856: ...MEMO 500 EN...