No.
Type
Details (Symptom, Possible Cause, Troubleshooting Procedures)
798
-3
B
Rear fence motor error
The rear jogger fence motor in the finisher is not operating.
• Rear jogger motor drive is obstructed (jammed paper, paper scraps, etc.)
• The rear jogger fence motor harness loose or broken
• Rear jogger fence HP sensor dirty, loose, defective
• Rear jogger fence motor defective
1. Check or replace the harness.
2. Check for blockages in the rear jogger motor drive mechanism.
3. Replace the rear jogger fence HP sensor.
4. Replace the rear jogger fence motor.
No.
Type
Details (Symptom, Possible Cause, Troubleshooting Procedures)
798
-4
B
Stack feed-out motor error
The stack feed-out HP sensor does not detect the home position of the stack feed-
out belt for a certain time after the stack feed-out belt has moved to its home position.
The stack feed-out HP sensor does not turn off for a certain time after the stack feed-
out belt has moved from its home position.
The 1st detection failure causes a jam error, and the 2nd failure causes this SC code.
• Defective stack feed-out HP sensor
• Overload on the stack feed-out motor
• Defective stack feed-out motor
• Defective main board
• Disconnected or defective harness
1. Check or replace the harness.
2. Check for blockages in the stack feed-out mechanism.
3. Replace the stack feed-out HP sensor.
4. Replace the stack feed-out motor.
5. Replace the main board.
SC Tables
93
3
Содержание MPC 2800 AT-C2
Страница 1: ...Model AT C2 Machine Code D023 D025 Field Service Manual July 2008 Subject to change...
Страница 2: ......
Страница 16: ...Overview Component Layout 1 Product Information 14 1...
Страница 125: ...6 Attach the on standby decal O to the right hand side of the main power switch Anti Condensation Heater Type A 123 2...
Страница 152: ...2 Installation 150 2...
Страница 156: ...3 Preventive Maintenance 154 3...
Страница 171: ...Left Cover 1 Left cover A x 6 Rear Cover 1 Rear cover A x 8 Exterior Covers 169 4...
Страница 176: ...3 Ozone filters A in the right top cover 4 Replacement and Adjustment 174 4...
Страница 243: ...3 Toner transport motor A x 3 x 1 Toner Collection Unit 1 Gear Unit p 228 Drive Unit 241 4...
Страница 249: ...6 Development clutch K A x 1 Drive Unit 247 4...
Страница 265: ...8 Thermopile F x 2 x 1 Fusing 263 4...
Страница 272: ...3 Open the duplex door A 4 Right door cover B x 4 5 Right door rear cover A x 3 4 Replacement and Adjustment 270 4...
Страница 286: ...Behind the IOB FCU and G3 Interface Unit F BICU G Controller Board H HDD 4 Replacement and Adjustment 284 4...
Страница 287: ...Controller Box Open I ITB Power Supply Board Electrical Components 285 4...
Страница 327: ...Controller Self Diagnostics 325 5...
Страница 347: ...6 Troubleshooting Service Call Conditions See Appendices for the following information SC Tables 345 6...
Страница 354: ...MEMO 352...
Страница 355: ...Model AT C2 Machine Code D023 D025 Appendices July 2008 Subject to change...
Страница 356: ......
Страница 359: ...SP1 xxx System and Others 496 SP2 XXX Scanning image quality 496 3...
Страница 360: ...4...
Страница 396: ...2 Appendix Maintenance Tables 40 2...
Страница 474: ...4 Appendix Process Control Error Conditions 118 4...
Страница 476: ...5 Appendix Troubleshooting Guide 120 5...
Страница 484: ...5 Appendix Troubleshooting Guide 128 5...
Страница 492: ...Sensor Locations 6 Appendix Jam Detection 136 6...
Страница 500: ...7 Appendix Electrical Component Defects 144 7...
Страница 854: ...MEMO 498...
Страница 855: ...MEMO 499...
Страница 856: ...MEMO 500 EN...