030 Max. Number Correction Threshold
*ENG
[0 to 99 / 5 / 1/step]
031 Max. Number Correction Counter
*ENG
[0 to 255 / 0 / 1/step]
3512
[Image Quality Adj.: Interval]
Adjusts the timing for execution of process control and line position adjustment.
001 During Job
*ENG
[0 to 100 / 30 / 1 page/step]
002 During Stand-by
*ENG
[0 to 100 / 10 / 1 minute/step]
3513
[PCU Motor Stop Time: Bk]
Displays the last time that the PCU motors stopped.
These are used for process control execution timing.
001 Year
*ENG
[0 to 99 / 0 / 1/step]
002 Month
*ENG
[1 to 12 / 1 / 1/step]
003 Date
*ENG
[1 to 31 / 1 / 1/step]
004 Hour
*ENG
[0 to 23 / 0 / 1/step]
005 Minute
*ENG
[0 to 59 / 0 / 1/step]
3514
[Environmental Display: Job End]
Displays the environmental conditions for the last job.
These are used for process control execution timing.
001 Temperature
*ENG
[-1280 to 1270 / 0 / 0.1°C/step]
002 Relative Humidity
*ENG
[0 to 1000 / - / 0.1%RH/step]
003 Absolute Humidity
*ENG
[0 to 1000 / - / 0.1 g/cm
3
/step]
3515
[Execution Interval: Display]
Displays the current interval for process control execution.
When the machine calculates the timing for process control, it uses a number of conditions.
These are the results after considering all the conditions.
001 Job End: Potential Control: BW
*ENG
[0 to 2000 / 500 / 1 page/step]
8. Appendix: SP Mode Tables
276
8
Содержание MPC 2800 AT-C2
Страница 1: ...Model AT C2 Machine Code D023 D025 Field Service Manual July 2008 Subject to change...
Страница 2: ......
Страница 16: ...Overview Component Layout 1 Product Information 14 1...
Страница 125: ...6 Attach the on standby decal O to the right hand side of the main power switch Anti Condensation Heater Type A 123 2...
Страница 152: ...2 Installation 150 2...
Страница 156: ...3 Preventive Maintenance 154 3...
Страница 171: ...Left Cover 1 Left cover A x 6 Rear Cover 1 Rear cover A x 8 Exterior Covers 169 4...
Страница 176: ...3 Ozone filters A in the right top cover 4 Replacement and Adjustment 174 4...
Страница 243: ...3 Toner transport motor A x 3 x 1 Toner Collection Unit 1 Gear Unit p 228 Drive Unit 241 4...
Страница 249: ...6 Development clutch K A x 1 Drive Unit 247 4...
Страница 265: ...8 Thermopile F x 2 x 1 Fusing 263 4...
Страница 272: ...3 Open the duplex door A 4 Right door cover B x 4 5 Right door rear cover A x 3 4 Replacement and Adjustment 270 4...
Страница 286: ...Behind the IOB FCU and G3 Interface Unit F BICU G Controller Board H HDD 4 Replacement and Adjustment 284 4...
Страница 287: ...Controller Box Open I ITB Power Supply Board Electrical Components 285 4...
Страница 327: ...Controller Self Diagnostics 325 5...
Страница 347: ...6 Troubleshooting Service Call Conditions See Appendices for the following information SC Tables 345 6...
Страница 354: ...MEMO 352...
Страница 355: ...Model AT C2 Machine Code D023 D025 Appendices July 2008 Subject to change...
Страница 356: ......
Страница 359: ...SP1 xxx System and Others 496 SP2 XXX Scanning image quality 496 3...
Страница 360: ...4...
Страница 396: ...2 Appendix Maintenance Tables 40 2...
Страница 474: ...4 Appendix Process Control Error Conditions 118 4...
Страница 476: ...5 Appendix Troubleshooting Guide 120 5...
Страница 484: ...5 Appendix Troubleshooting Guide 128 5...
Страница 492: ...Sensor Locations 6 Appendix Jam Detection 136 6...
Страница 500: ...7 Appendix Electrical Component Defects 144 7...
Страница 854: ...MEMO 498...
Страница 855: ...MEMO 499...
Страница 856: ...MEMO 500 EN...