031 Offset: Feed Start: F
*ENG
032 Feed: Glossy: Ready : U limit
*ENG
033 Offset: Feed Start: Glossy
*ENG
040 1bin: Paper Feed: Pressure Temp
*ENG
[0 to 100 / 85 / 1 deg/step]
041 F :1bin: Paper Feed: Pressure Temp
*ENG
[0 to 100 / 75 / 1 deg/step]
1105
[Fusing Temperature] Fusing Temperature Adjustment
(Printing Mode, Roller Type, [Color], Simplex/Duplex)
Roller Type –> Center and Ends: Heating roller, Pressure –> Pressure roller
Paper Type -> Plain, Thin, Thick, OHP, Middle Thick, Special
001
Fusing Ready Temp.
*ENG
[145 to 155 / 145 / 1 deg/step]
Specifies the heating roller target temperature for the ready condition.
002
Fusing Ready: Offset
*ENG
[15 to 30 / 15 / 1 deg/step]
Sets the heating roller offset temperature for the printing ready condition.
Ready temperature = (Target temperature specified in SP1-105-1) – Temperature specified
in this SP mode
007
Pressure Ready Temp
*ENG
[0 to 150 / 20 / 1 deg/step]
Sets the heating roller offset temperature at the end of the heating roller. This value is one of
the thresholds to determine if the machine is at the heating roller target temperature during
warm-up.
010 Stand-By: Center
* ENG
[140 to 170 / 155 / 1 deg/step]
011 Stand-By: End
* ENG
012
Stand-By: Pressure
* ENG
[105 to 135 / 120 / 1 deg/step]
Sets the pressure roller offset temperature. This value is one of the thresholds to determine if
the machine is at the heating roller target temperature during warm-up.
013 Panel Off Mode: Center
* ENG
[100 to 150 / 130 / 1 deg /step]
014 Panel Off Mode: Ends
* ENG
[100 to 150 / 130 / 1 deg /step]
015 Panel Off Mode: Pressure
*ENG
[105 to 135 / 120 / 1 deg /step]
8. Appendix: SP Mode Tables
150
8
Содержание MPC 2800 AT-C2
Страница 1: ...Model AT C2 Machine Code D023 D025 Field Service Manual July 2008 Subject to change...
Страница 2: ......
Страница 16: ...Overview Component Layout 1 Product Information 14 1...
Страница 125: ...6 Attach the on standby decal O to the right hand side of the main power switch Anti Condensation Heater Type A 123 2...
Страница 152: ...2 Installation 150 2...
Страница 156: ...3 Preventive Maintenance 154 3...
Страница 171: ...Left Cover 1 Left cover A x 6 Rear Cover 1 Rear cover A x 8 Exterior Covers 169 4...
Страница 176: ...3 Ozone filters A in the right top cover 4 Replacement and Adjustment 174 4...
Страница 243: ...3 Toner transport motor A x 3 x 1 Toner Collection Unit 1 Gear Unit p 228 Drive Unit 241 4...
Страница 249: ...6 Development clutch K A x 1 Drive Unit 247 4...
Страница 265: ...8 Thermopile F x 2 x 1 Fusing 263 4...
Страница 272: ...3 Open the duplex door A 4 Right door cover B x 4 5 Right door rear cover A x 3 4 Replacement and Adjustment 270 4...
Страница 286: ...Behind the IOB FCU and G3 Interface Unit F BICU G Controller Board H HDD 4 Replacement and Adjustment 284 4...
Страница 287: ...Controller Box Open I ITB Power Supply Board Electrical Components 285 4...
Страница 327: ...Controller Self Diagnostics 325 5...
Страница 347: ...6 Troubleshooting Service Call Conditions See Appendices for the following information SC Tables 345 6...
Страница 354: ...MEMO 352...
Страница 355: ...Model AT C2 Machine Code D023 D025 Appendices July 2008 Subject to change...
Страница 356: ......
Страница 359: ...SP1 xxx System and Others 496 SP2 XXX Scanning image quality 496 3...
Страница 360: ...4...
Страница 396: ...2 Appendix Maintenance Tables 40 2...
Страница 474: ...4 Appendix Process Control Error Conditions 118 4...
Страница 476: ...5 Appendix Troubleshooting Guide 120 5...
Страница 484: ...5 Appendix Troubleshooting Guide 128 5...
Страница 492: ...Sensor Locations 6 Appendix Jam Detection 136 6...
Страница 500: ...7 Appendix Electrical Component Defects 144 7...
Страница 854: ...MEMO 498...
Страница 855: ...MEMO 499...
Страница 856: ...MEMO 500 EN...