005 Offset: Bk
*ENG
These are additional values for calculating the
charge bias referring to the development bias at
process control.
[0 to 255 / 140 / 1 V/step]
DC charge bias = Development bias x (1 + 0.001
x SP3-241-001 to -004) + these values
006 Offset: M
*ENG
007 Offset: C
*ENG
008 Offset: Y
*ENG
3242
[LD Power Setting]
Adjusts the coefficient for LD power control value at the process control.
001 Coefficient: Bk
*ENG
[-1000 to 1000 / 61 / 1 /step]
002 Coefficient: M
*ENG
003 Coefficient: C
*ENG
004 Coefficient: Y
*ENG
005 Offset: Bk
*ENG
[-1000 to 1000 / 79 / 1 /step]
006 Offset: M
*ENG
007 Offset: C
*ENG
008 Offset: Y
*ENG
3251
[Coverage]
These (-001 to -016) are coefficients for SP3-222-009 to -012.
001 Latest: Bk
*ENG
Displays the latest coverage for each color.
[0 to 9999 / 0 / 1 cm
2
/step]
002 Latest: M
*ENG
003 Latest: C
*ENG
004 Latest: Y
*ENG
005-008
Displays the average coverage of each color for the Vtref correction.
"Average S" is defined when the number of developed pages does not reach the number
specified with SP3251-017.
8. Appendix: SP Mode Tables
266
8
Содержание MPC 2800 AT-C2
Страница 1: ...Model AT C2 Machine Code D023 D025 Field Service Manual July 2008 Subject to change...
Страница 2: ......
Страница 16: ...Overview Component Layout 1 Product Information 14 1...
Страница 125: ...6 Attach the on standby decal O to the right hand side of the main power switch Anti Condensation Heater Type A 123 2...
Страница 152: ...2 Installation 150 2...
Страница 156: ...3 Preventive Maintenance 154 3...
Страница 171: ...Left Cover 1 Left cover A x 6 Rear Cover 1 Rear cover A x 8 Exterior Covers 169 4...
Страница 176: ...3 Ozone filters A in the right top cover 4 Replacement and Adjustment 174 4...
Страница 243: ...3 Toner transport motor A x 3 x 1 Toner Collection Unit 1 Gear Unit p 228 Drive Unit 241 4...
Страница 249: ...6 Development clutch K A x 1 Drive Unit 247 4...
Страница 265: ...8 Thermopile F x 2 x 1 Fusing 263 4...
Страница 272: ...3 Open the duplex door A 4 Right door cover B x 4 5 Right door rear cover A x 3 4 Replacement and Adjustment 270 4...
Страница 286: ...Behind the IOB FCU and G3 Interface Unit F BICU G Controller Board H HDD 4 Replacement and Adjustment 284 4...
Страница 287: ...Controller Box Open I ITB Power Supply Board Electrical Components 285 4...
Страница 327: ...Controller Self Diagnostics 325 5...
Страница 347: ...6 Troubleshooting Service Call Conditions See Appendices for the following information SC Tables 345 6...
Страница 354: ...MEMO 352...
Страница 355: ...Model AT C2 Machine Code D023 D025 Appendices July 2008 Subject to change...
Страница 356: ......
Страница 359: ...SP1 xxx System and Others 496 SP2 XXX Scanning image quality 496 3...
Страница 360: ...4...
Страница 396: ...2 Appendix Maintenance Tables 40 2...
Страница 474: ...4 Appendix Process Control Error Conditions 118 4...
Страница 476: ...5 Appendix Troubleshooting Guide 120 5...
Страница 484: ...5 Appendix Troubleshooting Guide 128 5...
Страница 492: ...Sensor Locations 6 Appendix Jam Detection 136 6...
Страница 500: ...7 Appendix Electrical Component Defects 144 7...
Страница 854: ...MEMO 498...
Страница 855: ...MEMO 499...
Страница 856: ...MEMO 500 EN...