No.
Type
Details (Symptom, Possible Cause, Troubleshooting Procedures)
992
CTL
D
Undefined error
Defective software program
• An error undetectable by any other SC code occurred
No.
Type
Details (Symptom, Possible Cause, Troubleshooting Procedures)
994
CTL
C
Operation panel management records exceeded
An error occurred because the number of records exceeded the limit for images
managed in the service layer of the firmware. This can occur if there if there are too
many application screens open on the operation panel.
• No action required because this SC does not interfere with operation of the
machine.
No.
Type
Details (Symptom, Possible Cause, Troubleshooting Procedures)
995
D
CPM setting error
-001
• Defective BICU
• NVRAM Replacement error
1. Install the previous NVRAM.
2. Input the serial number with SP5811-004, and turn the main power switch off/
on.
-002
• Defective NVRAM
• Defective controller
1. Update the controller firmware.
2. Install a new NVRAM, and turn off and on the main power switch after
SC995-002 has occurred.
-003
• Incorrect type controller installed
• Defective controller
1. Replace the controller with the correct type.
-004
• Incorrect model controller installed.
1. Replace the controller with the correct model.
3. Appendix: Service Call Conditions
110
3
Содержание MPC 2800 AT-C2
Страница 1: ...Model AT C2 Machine Code D023 D025 Field Service Manual July 2008 Subject to change...
Страница 2: ......
Страница 16: ...Overview Component Layout 1 Product Information 14 1...
Страница 125: ...6 Attach the on standby decal O to the right hand side of the main power switch Anti Condensation Heater Type A 123 2...
Страница 152: ...2 Installation 150 2...
Страница 156: ...3 Preventive Maintenance 154 3...
Страница 171: ...Left Cover 1 Left cover A x 6 Rear Cover 1 Rear cover A x 8 Exterior Covers 169 4...
Страница 176: ...3 Ozone filters A in the right top cover 4 Replacement and Adjustment 174 4...
Страница 243: ...3 Toner transport motor A x 3 x 1 Toner Collection Unit 1 Gear Unit p 228 Drive Unit 241 4...
Страница 249: ...6 Development clutch K A x 1 Drive Unit 247 4...
Страница 265: ...8 Thermopile F x 2 x 1 Fusing 263 4...
Страница 272: ...3 Open the duplex door A 4 Right door cover B x 4 5 Right door rear cover A x 3 4 Replacement and Adjustment 270 4...
Страница 286: ...Behind the IOB FCU and G3 Interface Unit F BICU G Controller Board H HDD 4 Replacement and Adjustment 284 4...
Страница 287: ...Controller Box Open I ITB Power Supply Board Electrical Components 285 4...
Страница 327: ...Controller Self Diagnostics 325 5...
Страница 347: ...6 Troubleshooting Service Call Conditions See Appendices for the following information SC Tables 345 6...
Страница 354: ...MEMO 352...
Страница 355: ...Model AT C2 Machine Code D023 D025 Appendices July 2008 Subject to change...
Страница 356: ......
Страница 359: ...SP1 xxx System and Others 496 SP2 XXX Scanning image quality 496 3...
Страница 360: ...4...
Страница 396: ...2 Appendix Maintenance Tables 40 2...
Страница 474: ...4 Appendix Process Control Error Conditions 118 4...
Страница 476: ...5 Appendix Troubleshooting Guide 120 5...
Страница 484: ...5 Appendix Troubleshooting Guide 128 5...
Страница 492: ...Sensor Locations 6 Appendix Jam Detection 136 6...
Страница 500: ...7 Appendix Electrical Component Defects 144 7...
Страница 854: ...MEMO 498...
Страница 855: ...MEMO 499...
Страница 856: ...MEMO 500 EN...