003
Low Temp. Correction
*ENG
[0 to 15 / 5 / 1 deg/step]
Specifies the temperature correction for the heating roller. When the low temperature
condition (specified with SP1112-001) is detected, the value of this SP is added to the
heating roller temperature.
004
High Temp. Correction
*ENG
[0 to 15 / 5 / 1 deg/step]
Specifies the temperature correction for the heating roller. When the high temperature
condition (specified with SP1112-002) is detected, the value of this SP is subtracted from
the heating roller temperature.
005 Low Temp. Correction: Paper Feed *ENG
[0 to 15 / 6.5 / 0.1 deg/step]
006
High Temp. Correction: Paper
Feed
*ENG
[0 to 15 / 5 / 1 deg/step]
1113
[Stand-by Time]
001
After Ready
*ENG
[0 to 60 / 20 / 1 sec/step]
003
After Recovery
*ENG
[0 to 60 / 10 / 1 sec/step]
Specifies the time for keeping the target temperature after recovery (SP1105-083) without
any jobs.
004
After Job
*ENG
[0 to 60 / 10 / 1 sec/step]
005
PressureTemp: After Ready
*ENG
[0 to 160 / 100 / 1 deg/step]
006
Pressure Temp: After Job
*ENG
008
ON/OFF Time Switch
*ENG
[0 to 999 / 300 / 1 sec/step]
1115
[Stand-by Idling]
001
Interval
*ENG
[1 to 240 / 60 / 1 min/step]
Specifies the interval between idling during stand-by mode.
This idling during the stand-by mode prevents the roller deformation.
002
Idling Time
*ENG
[1 to 60 / 2 / 0.1 sec/step]
Specifies the length of each idling operation during stand-by mode.
003 Idling Speed
*ENG
[0 to 1 / 0 / 1 mm/sec/step]
System Service Mode
157
8
Содержание MPC 2800 AT-C2
Страница 1: ...Model AT C2 Machine Code D023 D025 Field Service Manual July 2008 Subject to change...
Страница 2: ......
Страница 16: ...Overview Component Layout 1 Product Information 14 1...
Страница 125: ...6 Attach the on standby decal O to the right hand side of the main power switch Anti Condensation Heater Type A 123 2...
Страница 152: ...2 Installation 150 2...
Страница 156: ...3 Preventive Maintenance 154 3...
Страница 171: ...Left Cover 1 Left cover A x 6 Rear Cover 1 Rear cover A x 8 Exterior Covers 169 4...
Страница 176: ...3 Ozone filters A in the right top cover 4 Replacement and Adjustment 174 4...
Страница 243: ...3 Toner transport motor A x 3 x 1 Toner Collection Unit 1 Gear Unit p 228 Drive Unit 241 4...
Страница 249: ...6 Development clutch K A x 1 Drive Unit 247 4...
Страница 265: ...8 Thermopile F x 2 x 1 Fusing 263 4...
Страница 272: ...3 Open the duplex door A 4 Right door cover B x 4 5 Right door rear cover A x 3 4 Replacement and Adjustment 270 4...
Страница 286: ...Behind the IOB FCU and G3 Interface Unit F BICU G Controller Board H HDD 4 Replacement and Adjustment 284 4...
Страница 287: ...Controller Box Open I ITB Power Supply Board Electrical Components 285 4...
Страница 327: ...Controller Self Diagnostics 325 5...
Страница 347: ...6 Troubleshooting Service Call Conditions See Appendices for the following information SC Tables 345 6...
Страница 354: ...MEMO 352...
Страница 355: ...Model AT C2 Machine Code D023 D025 Appendices July 2008 Subject to change...
Страница 356: ......
Страница 359: ...SP1 xxx System and Others 496 SP2 XXX Scanning image quality 496 3...
Страница 360: ...4...
Страница 396: ...2 Appendix Maintenance Tables 40 2...
Страница 474: ...4 Appendix Process Control Error Conditions 118 4...
Страница 476: ...5 Appendix Troubleshooting Guide 120 5...
Страница 484: ...5 Appendix Troubleshooting Guide 128 5...
Страница 492: ...Sensor Locations 6 Appendix Jam Detection 136 6...
Страница 500: ...7 Appendix Electrical Component Defects 144 7...
Страница 854: ...MEMO 498...
Страница 855: ...MEMO 499...
Страница 856: ...MEMO 500 EN...