CLM01.4-LAP-01VRS
Diagnostic Messages
11-9
DOK-CONTRL-CLM01.4LAP1-FK01-EN-P
S y s t e m
F a i l u r e
!
Hex Code 11
C o d e
# I R Q O V L
Serious internal error. Interrupt overlap, pseudo exception.
⇒
The internal timing of the CLM has been exceeded. The cycle time in
Parameter B010 may need to be incremented by one.
S y s t e m
F a i l u r e
!
Hex Code 11
- Contact INDRAMAT Customer Service! -
C o d e
# E P R O M
Serious internal error. Loss of EPROM data, pseudo exception.
⇒
The data in the EPROM have changed. Operation is impossible. The
EPROM must be replaced.
E R R O R
Hex Code 12
I D S
B r e a k - E r r o r
This error will occur if the optional IDS board is enabled, but the CLM
does not detect the connection of the IDS board.
The IDS board is enabled in parameter B002.
1.
The cable between the IDS board and the CLM connector X6 is
not installed properly.
2.
The CLM serial communication port is defective.
3.
The IDS board is defective.
E R R O R
Hex Code 13
I D S
C h e c k s u m
E r r
This error will occur if the optional IDS board is enabled, but the CLM
does not detect the connection of the IDS board.
The IDS board is enabled in parameter B002.
1.
The cable between the IDS board and the CLM connector X6 is
not installed properly.
2.
If the IDS board is connected, then the wiring and its layout to the
decade switch should be checked. Maximum cable length is 15m.
Содержание CLM1.4
Страница 117: ...7 20 Functions CLM01 4 LAP 01VRS DOK CONTRL CLM01 4LAP1 FK01 EN P Notes...
Страница 205: ...9 42 Interfaces CLM01 4 LAP 01VRS DOK CONTRL CLM01 4LAP1 FK01 EN P Notes...
Страница 213: ...10 8 Command Communications CLM01 4 LAP 01VRS DOK CONTRL CLM01 4LAP1 FK01 EN P Notes...
Страница 233: ...11 20 Diagnostic Messages CLM01 4 LAP 01VRS DOK CONTRL CLM01 4LAP1 FK01 EN P Notes...
Страница 272: ......
Страница 273: ...Printed in the U S A Barcode...