CLM01.4-LAP-01VRS
Diagnostic Messages
11-17
DOK-CONTRL-CLM01.4LAP1-FK01-EN-P
E R R O R
Hex Code for
Axis 1 = 48
A x i s
X
N o t
H o m e d
Axis 2 = 78
Axis 3 = A8
Axis 4 = D8
In the program, a command that requires an axis with an absolute
reference point was invoked.
⇒
The following commands are affected: POA, PSA, VCC.
⇒
Before invoking these commands, the axis must be designated as
absolute (see ’Homing’ and Parameters Ax23 to Ax25).
E R R O R
Hex Code for
Axis 1 = 49
C a m
t o o
s h o r t
X
Axis 2 = 79
Axis 3 = A9
Axis 4 = D9
No marker pulse was found for the encoder in the homing cycle.
⇒
The home switch cam is too short. The cam must reach one end of
the travel distance (see ’Homing’).
E R R O R
Hex Code for
Axis 1 = 4A
N o
M a r k e r
P u l s e X
Axis 2 = 7A
Axis 3 = AA
Axis 4 = DA
No marker pulse was detected within one revolution of the encoder during
the homing cycle. (see ’Homing’).
⇒
Check the cable connection, to verify whether the marker pulse signals
might be inverted or the marker pulse is not connected.
⇒
The encoder does not issue a marker pulse.
E R R O R
Hex Code for
Axis 1 = 4B
M r k r P u l s e
P o s
A X
Axis 2 = 7B
Axis 3 = AB
Axis 4 = DB
In the homing cycle, it has been determined that the distance between the
marker pulse for the incremental encoder and the edge of the homing
switch cam is less than 1/16 revolution or greater than 15/16 revolution.
Содержание CLM1.4
Страница 117: ...7 20 Functions CLM01 4 LAP 01VRS DOK CONTRL CLM01 4LAP1 FK01 EN P Notes...
Страница 205: ...9 42 Interfaces CLM01 4 LAP 01VRS DOK CONTRL CLM01 4LAP1 FK01 EN P Notes...
Страница 213: ...10 8 Command Communications CLM01 4 LAP 01VRS DOK CONTRL CLM01 4LAP1 FK01 EN P Notes...
Страница 233: ...11 20 Diagnostic Messages CLM01 4 LAP 01VRS DOK CONTRL CLM01 4LAP1 FK01 EN P Notes...
Страница 272: ......
Страница 273: ...Printed in the U S A Barcode...