CLM01.4-LAP-01VRS
Command Communications
10-1
DOK-CONTRL-CLM01.4LAP1-FK01-EN-P
10 Command
Communications
10.1 Profibus
Rexroth Indramat provides advanced drive technology with a user-friendly
interface. This is how, for example, homing and jogging were defined as
individual operating modes in the DriveCom product. Rexroth Indramat
has provided this functionality (as also defined in the ProfiDrive) as bits in
the control word, and thus can now offer an interface that is easier to use.
The slave address is set in Parameter B008.
Status at Delivery:
The CLM1.4 address is set to 00 at delivery.
Slave addresses 1-99 (decimal) are supported.
Depending on the fieldbus type, however, the following limitations exist:
Profibus DP address:
2 - 89 permitted
Note:
Slave address 0 does not exist and cannot be used in
applications.
The address is read from Parameter Mode to the operating mode when
starting up the CLM, and it is used to set the parameters for the fieldbus.
To set the slave address, parameter input X3/1 is used. This input is
dominant and is used for the initial startup of the control.
The data channel size is 32 bytes.
Service Data Channel
Process Data Channel
6 Words
8 (7) Words
Fig. 10-1: Transmission
Setting the Slave Address
Settable Addresses:
Slave Address
Содержание CLM1.4
Страница 117: ...7 20 Functions CLM01 4 LAP 01VRS DOK CONTRL CLM01 4LAP1 FK01 EN P Notes...
Страница 205: ...9 42 Interfaces CLM01 4 LAP 01VRS DOK CONTRL CLM01 4LAP1 FK01 EN P Notes...
Страница 213: ...10 8 Command Communications CLM01 4 LAP 01VRS DOK CONTRL CLM01 4LAP1 FK01 EN P Notes...
Страница 233: ...11 20 Diagnostic Messages CLM01 4 LAP 01VRS DOK CONTRL CLM01 4LAP1 FK01 EN P Notes...
Страница 272: ......
Страница 273: ...Printed in the U S A Barcode...