8-36
Parameters
CLM01.4-LAP-01VRS
DOK-CONTRL-CLM01.4LAP1-FK01-EN-P
B018 Clear Outputs
C l e a r
O u t p u t s
B 0 1 8
0
1 2 3 4 5 6 7
Outputs Q1.06
Outputs Q1.05
Outputs Q1.04
Outputs Q1.03
Outputs Q1.02
Outputs Q1.01
Outputs Q1.00
Fault code via outputs (Outputs Q1.00 – Q1.05)
0 = Function not enabled
1 = Fault code via outputs Q1.00
2 = Fault code via outputs Q1.01
3 = Fault code via outputs Q1.02
4 = Fault code via outputs Q1.03
5 = Fault code via outputs Q1.04
6 = Fault code via outputs Q1.05
Clear Outputs
This function allows the user to influence the clearing of outputs when
faults occur.
For each group of 8 outputs, the following inputs are possible:
0 =
Clear outputs when a fault or E-STOP occurs.
1 =
Do not clear outputs when a fault or E-STOP occurs. The outputs
are only cleared after the fault has been cleared.
2 =
Do not clear outputs when error or E-STOP occurs or is cleared
('Clear' key, external 'Clear').
Note:
If the BB relay drops out, all outputs present in the hardware
are shut off internally.
Fault Code via Outputs
00 to 3F - General fault
40 to 6F - Fault, Axis 1
70 to 9F - Fault, Axis 2
A0 to CF - Fault, Axis 3
D0 to FF - Fault, Axis 4
Содержание CLM1.4
Страница 117: ...7 20 Functions CLM01 4 LAP 01VRS DOK CONTRL CLM01 4LAP1 FK01 EN P Notes...
Страница 205: ...9 42 Interfaces CLM01 4 LAP 01VRS DOK CONTRL CLM01 4LAP1 FK01 EN P Notes...
Страница 213: ...10 8 Command Communications CLM01 4 LAP 01VRS DOK CONTRL CLM01 4LAP1 FK01 EN P Notes...
Страница 233: ...11 20 Diagnostic Messages CLM01 4 LAP 01VRS DOK CONTRL CLM01 4LAP1 FK01 EN P Notes...
Страница 272: ......