11-8
Diagnostic Messages
CLM01.4-LAP-01VRS
DOK-CONTRL-CLM01.4LAP1-FK01-EN-P
E R R O R
Hex Code 0E
I n v a l i d
B l o c k
#
The program contains a jump or branch command that causes the CLM
user program to jump to a program block greater than 2999.
NOTE: If Task 3 is being used, enter the Task 3 program in the
appropriate program block location before enabling the Task 3 program in
parameter B011.
1.
The BIC program commands can result in a jump or branch to a
target block greater than 2999. This jump is caused by a
combination of an offset, jump distance, or binary input. Refer to
chapter programming to determine if the program command is
used properly.
2.
The branch or jump command contains an asterisk (*) in the
target block. Refer to chapter programming to determine if the
program command is used properly.
S y s t e m
F a i l u r e
!
Hex Code 10
C o d e
# E X C P X X
A significant error occurred.
⇒
The external wiring must be checked.
Note:
If this error has not yet been cleared using the key, more
details can be specified for troubleshooting by Customer
Service. To do this, proceed as follows:
1)
Press
on the CLM keypad.
2)
Take note of the code ’XX.’
3)
Take note of all information that appears by pressing the
or
keys.
4)
Clear the error.
5)
Take note of the firmware version that appears on the
CLM display.
S y s t e m
F a i l u r e
!
Hex Code 11
- Contact INDRAMAT Customer Service! -
C o d e
# S T K O V F
Serious internal error. Stack overflow, pseudo exception.
⇒
A firmware error may be present.
Содержание CLM1.4
Страница 117: ...7 20 Functions CLM01 4 LAP 01VRS DOK CONTRL CLM01 4LAP1 FK01 EN P Notes...
Страница 205: ...9 42 Interfaces CLM01 4 LAP 01VRS DOK CONTRL CLM01 4LAP1 FK01 EN P Notes...
Страница 213: ...10 8 Command Communications CLM01 4 LAP 01VRS DOK CONTRL CLM01 4LAP1 FK01 EN P Notes...
Страница 233: ...11 20 Diagnostic Messages CLM01 4 LAP 01VRS DOK CONTRL CLM01 4LAP1 FK01 EN P Notes...
Страница 272: ......
Страница 273: ...Printed in the U S A Barcode...