CLM01.4-LAP-01VRS
Parameters
8-13
DOK-CONTRL-CLM01.4LAP1-FK01-EN-P
Ax10 Jerk Constant
J e r k
C o n s t a n t
A x
A x 1 0
0 . 2 3 4
Time constant for acceleration change (sec)
Input range: 0.000 to 1.024
0 = Jerk limiting inactive, constant acceleration
The ’Time Constant for Acceleration’ sets the time during which the CLM
accelerates. Internally, the CLM rounds the time constant up.
n
2
(ms)
Time
Cycle
Loop
Position
1000
(s)
Constant
Jerk
=
×
Fig. 8-5: Calculation of the Time Constant
Jerk1_AE.WMF
Fig. 8-6: Jerk Limiting