10
Remeha Avanta Plus
R
3x
LTNLW6H000073A
R
4x
LTNLW6H000074A
In the comfort mode the boiler will be seen to run
occasionally even if time clocks are in the off position.
0
= Comfort mode
1
= Eco mode
2
= regulated by controller (= factory setting)
Change the mode as follows:
LT.NL.W6H.000.073
•
Press
‘Enter’- key
until codes
p
[
and
[
1
are dis-
played alternately.
•
Press
[+]- key
3x until codes
p
[
and
[
4
are dis-
played alternately.
•
Press
‘Enter’- key
; setting of ‘eco or heat retention’ mode
is displayed (mode
2
= heat retention and regulator-
dependent, factory setting).
•
Press
[-]-
key
to change this mode, for example mode
1
(=eco mode).
•
Press
‘Enter’- key
to confirm this mode; codes
p
[
and
[
4
are displayed alternately.
•
Press
‘Reset’- key
to switch boiler to operating mode.
Changing P5 setting: (no) anticipated current
Boiler responds to temperature changes after a certain time,
input via on/off thermostat. Response time can be reduced by
enabling ‘Anticipated current’ option (only when the on/off ther-
mostat has an anticipation current setting device). When the
boiler is installed this setting has been already been adjusted.
Ask your service engineer for further details.
Change the anticipated current (if necessary) setting as fol-
lows:
LT.NL.W6H.000.074
•
Press
‘Enter’- key
for 1 second until codes
p
[
and
[
1
are displayed alternately.
•
Press
[+]- key
4x until codes
p
[
and
[
5
are dis-
played alternately.
•
Press
‘Enter’- key
; (no) anticipated current setting is dis-
played (mode 0 = no anticipated current, factory setting).
•
Press
[-]-
key
to change this mode, for example mode 1
(=anticipated current).
•
Press
‘Enter’- key
to confirm this mode; codes
p
[
and
[
5
are displayed alternately.
•
Press
‘Reset’- key
to switch boiler to operating mode.
Содержание Avanta Plus 24s
Страница 94: ...30...
Страница 95: ...31...
Страница 97: ...2 AVANTA PLUS 28 Combi Gas Council No 47 673 02 39 Combi Gas Council No 47 673 04...
Страница 100: ...5...
Страница 104: ...9...
Страница 107: ...12 AVANTA PLUS 24 System Gas Council No 41 288 05...
Страница 110: ...15...
Страница 118: ...User guide Remeha Avanta Plus Remeha Avanta Plus 28c Remeha Avanta Plus 39c Remeha Avanta Plus 24s...
Страница 146: ...1 Issue No 1 Date 8 December 2005 Operating instructions for the built in Two Channel Digital electronic time clock...
Страница 149: ...4 6 Description of setting buttons and display M T W Th F S Su DAY HR MIN Set 5 Position of Timer in boiler when fitted...