53
R
•
Press the
[enter]
-key and keep it pressed;
•
Press the
[reset]
-key until codes
c
and
0
appear alter-
nately in the display;
•
Enter the special access code
88
with the
[+]
or
[-]-
key;
•
Press the
[enter]
-key; the display shows
ér
and the
number of the last error alternately, for
example
02
.
•
Press the
[+]
or
[-]-
key to go forwards or backwards in the
list of errors.
•
Press the
[enter]
-key to take a closer look ot the error. The
display shows the error code as follows;
- first error code
é
with error number e.g.
12
-
then status code
5t
with status number e.g.
3
(burning
for central heating)
-
then number of time that the error has occurred
ñ
and a
number e.g.
3
-
then the flow temperature when the error occurred
t1
and temperature e.g.
75
-
final the return temperature when the error occurred
t2
and temperature e.g.
60
This cycle continues to repeat itself.
•
Press the
[reset]
-key to stop the cycle; the following
appears in the display;
ér
and the last viewed errors e.g the numbers
1
and
8
.
•
Press the
[+]
or
[-]-
key to look at the following error data.
4.4.2 Deleting errors
The last message in the list,
Er
followed by
cl
will
appear in the display;
•
Press the
[enter]
-key again, and the following will appear in
the display:
0
•
Press the
[+]
-key to set the parameter to
1
.
•
Press the
[enter]
-key, to delete the error memory:
•
Press the
[escape]
-key twice to exit the error memory.
o
When tracing an error, the cause can often be found more
quickly if the operating status at the time the error occurred
can be retrieved from the error memory.
4.4 Error memory
The Remeha Avanta Plus control unit has an error memory,
in which the last 16 errors are stored. In addition to the error
code (
é
and a number
xx
).
The following data is also stored:
•
the number of times the error occurred (
n
and a number
xx
)
•
the operating status of the boiler (
5t
and a number
xx
)
•
the flow temperature (
t1
and the value
xx
) return tem-
perature (
t2
and the value
xx
) at the time the error
occurred.
To get access to the error memory, access code must be
entered.
4.4.1 Error read outs
LT.AL.W7H.000.064
Содержание Avanta Plus 24s
Страница 94: ...30...
Страница 95: ...31...
Страница 97: ...2 AVANTA PLUS 28 Combi Gas Council No 47 673 02 39 Combi Gas Council No 47 673 04...
Страница 100: ...5...
Страница 104: ...9...
Страница 107: ...12 AVANTA PLUS 24 System Gas Council No 41 288 05...
Страница 110: ...15...
Страница 118: ...User guide Remeha Avanta Plus Remeha Avanta Plus 28c Remeha Avanta Plus 39c Remeha Avanta Plus 24s...
Страница 146: ...1 Issue No 1 Date 8 December 2005 Operating instructions for the built in Two Channel Digital electronic time clock...
Страница 149: ...4 6 Description of setting buttons and display M T W Th F S Su DAY HR MIN Set 5 Position of Timer in boiler when fitted...