26
Remeha Avanta Plus
10 EXPANDING THE CENTRAL HEATING SYSTEM
Connecting thermostats
A 2-wire on/off thermostat (e.g. the Remeha Celcia 10) or to a
modulating thermostat (e.g. the Remeha Celcia 15 or 20) can
be connected to the Avanta Plus. Consult the installer about
connecting the thermostat you have chosen.
Connecting an under floor heating system
A under floor heating system can be directly connected to the
Avanta Plus
(provided it is sealed to prevent oxygen diffusion).
Consult the installer about connecting to a floor heating sys-
tem.
Use of solar panels
The Remeha Avanta Plus is suitable for use as a post-heater
for solar panels. Consult the installer about installing a solar
panel.
11
TECHNICAL DATA
Appliance type Remeha Avanta
Plus
24s
system
28c
combi
39c
combi
General
Boiler control
on/off or modulating
1)
Nominal central heating capacity (80/60°C)
kW
21.6
21.6
33.3
Assembly dry weight
kg
29.0
30.5
34.5
Noise level at distance of 1m from the boiler (at full load)
dB(A)
< 44
4)
Gas and flue details
Gas consumption natural gas maximum
m
n
3
/h
2.3
3.0
3.9
Gas flue rate
kg/h
37
47
62
CH side
Water capacity heat exchanger and piping
l
1.8
1.8
2.2
Minimum operating water pressure
bar
0.8
Maximum operating water pressure
PMS
bar
3.0
Water temperature maximum
°C
110
Operating temperature maximum
°C
95
Domestic hot water side
1
)
Tap capacity (35°C)
l/min
-
11.4
15.9
Minimum tap flow
2)
l/min
-
1.2
1.2
Electrical
Main supply
V/Hz
230 / 50
Power consumption
W
maximum
W
115
115
180
Degree of protection
IP
X4D
3)
1)
=
a modulating boiler permits infinitely adjustable matching
of heat production to heat demand.
2)
= minimum flow rate of water from the tap to start the boiler
running.
3)
= splash proof; under certain circumstances the boiler may
be installed in damp rooms such as bathrooms. Check
with
your installer.
4)
= noise level of a quiet conversation.
Содержание Avanta Plus 24s
Страница 94: ...30...
Страница 95: ...31...
Страница 97: ...2 AVANTA PLUS 28 Combi Gas Council No 47 673 02 39 Combi Gas Council No 47 673 04...
Страница 100: ...5...
Страница 104: ...9...
Страница 107: ...12 AVANTA PLUS 24 System Gas Council No 41 288 05...
Страница 110: ...15...
Страница 118: ...User guide Remeha Avanta Plus Remeha Avanta Plus 28c Remeha Avanta Plus 39c Remeha Avanta Plus 24s...
Страница 146: ...1 Issue No 1 Date 8 December 2005 Operating instructions for the built in Two Channel Digital electronic time clock...
Страница 149: ...4 6 Description of setting buttons and display M T W Th F S Su DAY HR MIN Set 5 Position of Timer in boiler when fitted...