Other problems
Problem or error
Possible cause
Solution/points to check
A.
No hot water when tap is
turned on
Boiler is not running
Check whether the boiler is switched on
check whether a fuse has blown;
check whether the gas tap is properly open.
Water pressure is too low (less than 1
bar)
Check mains cold water pressure
Economy shower head is letting too little
water through
Remove the shower head and clean; fit a new shower
head if necessary
B.
Radiators are not
(properly) hot
Room thermostat is set too low
Set room thermostat higher
Radiator valve is not open
Open radiator valve (further)
Boiler is not running
Check whether the boiler is switched on
check whether a fuse has blown;
check whether the gas tap is properly open.
System pressure too low
Top up central heating;
see par.5.1
C.
Boiler not working
Room thermostat is set too low
Set room thermostat higher
Boiler is not running
Check whether the boiler is switched on
check whether a fuse has blown;
check whether the gas tap is properly open.
System pressure is too low
Top up central heating,
see par. 5.1
Boiler has a fault
Reset the boiler (using the ‘Reset’ key);
remedy the fault (
see par. 4.1
) or
consult your installer (
see par. 4.2
).
Gas pressure is too low
Check gas pressure at boiler and meter
D.
System water pressure is
too low (less than 1 bar)
Insufficient water in central heating sys-
tem
Top up central heating;
see par 5.1
Water leak
Consult installer
E.
Major temperature
fluctuations in the DHW
Water supply insufficient
Check supply pressure : Open water tap further
F.
Ticking noises from
central heating pipes
Central heating pipes clipped too tightly
Loosen clips;
lubricate clips with grease;
enlarge sleeves (in walls and/or floors).
G.
Gurgling noises in cen-
tral heating pipes and/or
radiators
Air in central heating system
Bleed central heating and top up system afterwards;
see par.
5.2
H.
Flow noises in
central heating pipes
Water in central heating system
flowing too quickly
Consult installer
I.
Serious leak under or
near boiler
Boiler or central heating pipes
are faulty or damaged
Consult installer
Error codes
When contacting your installer, please have details of the error
code on the display, the serial number, year of manufacture
and type of the boiler (see label on base of the boiler).
Содержание Avanta Plus 24s
Страница 94: ...30...
Страница 95: ...31...
Страница 97: ...2 AVANTA PLUS 28 Combi Gas Council No 47 673 02 39 Combi Gas Council No 47 673 04...
Страница 100: ...5...
Страница 104: ...9...
Страница 107: ...12 AVANTA PLUS 24 System Gas Council No 41 288 05...
Страница 110: ...15...
Страница 118: ...User guide Remeha Avanta Plus Remeha Avanta Plus 28c Remeha Avanta Plus 39c Remeha Avanta Plus 24s...
Страница 146: ...1 Issue No 1 Date 8 December 2005 Operating instructions for the built in Two Channel Digital electronic time clock...
Страница 149: ...4 6 Description of setting buttons and display M T W Th F S Su DAY HR MIN Set 5 Position of Timer in boiler when fitted...