34
Remeha Avanta Plus
2.9.5 Error during the start-up procedure
•
If the display is blank (should show dots or letters), check:
- 230 V main supply available to switch spur
- switch spur fuse
-
cable and connections between the switched spur and the
boiler control unit
- fuse on the boiler control unit (F2 = 2AT, 230V)
•
An error code appearing in the display can be recognised
as follows:
é 10
, (the display alternately shows an
é
and a
number e.g.
10
). The meaning of this error codes can be
found in the error table, see
Chapter 4.
•
Resolve the error first if possible.
•
Press the
[reset]
- key and hold for at least 1 second to
restart the boiler.
z
After any error
é1
,
é2
,
é7
,
é10
or
é13
; the 3
minute venting cycle will run first before starting the boiler.
•
Checking
DHW
function;
- Turn on a hot water tap, the display shows:
[1
; pre-purge stage
[2
; Ignition stage
[4
; operating in DHW mode
-
Close the hot water tap, after a short time the display
shows:
[1
; pre-purge stage
[7
; pump run on after CH or DHW is satisfied
[0
; stand-by mode
•
Checking
CH
function;
- Ensure the time control is in the CH on position
-
Set the room thermostat on a high demanding tempera-
ture and, the display shows
[1
; pre-purge stage
[2
; Ignition stage
[3
; operating in CH mode.
-
Set the room thermostat back to a lower temperature (no
more heat demand), the display shows:
[4
; operating in DHW mode (boost to DHW plate on
minimum load)
[5
; waiting-time: 3 to 10 minutes (only when flow tem-
perature has already been reached and heating demand is
still existing)
[1
; pre-purge stage
[7
; pump run on after CH or DHW is satisfied
[0
; stand-by mode
Содержание Avanta Plus 24s
Страница 94: ...30...
Страница 95: ...31...
Страница 97: ...2 AVANTA PLUS 28 Combi Gas Council No 47 673 02 39 Combi Gas Council No 47 673 04...
Страница 100: ...5...
Страница 104: ...9...
Страница 107: ...12 AVANTA PLUS 24 System Gas Council No 41 288 05...
Страница 110: ...15...
Страница 118: ...User guide Remeha Avanta Plus Remeha Avanta Plus 28c Remeha Avanta Plus 39c Remeha Avanta Plus 24s...
Страница 146: ...1 Issue No 1 Date 8 December 2005 Operating instructions for the built in Two Channel Digital electronic time clock...
Страница 149: ...4 6 Description of setting buttons and display M T W Th F S Su DAY HR MIN Set 5 Position of Timer in boiler when fitted...