7
10. Checking the Timer settings
To check and edit existing times or to add new times
⇒
Set program switches 7 to
AUTO
and 8 to
P1 or P2
- the display will show the first
ON time set with the day or group of days it applies to
⇒
Button P to select first off time - again the display will show the first OFF time set
with the day or group of days it applies to
Repeat button P to scroll through each ON and Off setting time editing where necessary
Note: See section 11. for programming errors
11. Skip Function - Timer override
The skip or override function changes the current switching mode of the timer channel P1 or P2
from ON to OFF or from OFF to ON until the next programmed switching time
⇒
Set program switches 7 to
AUTO
and 8 to
RUN
To override channel P1 - Heating
⇒
Button
–X->
once
1
will appear to the right of the time display (ie: 6.30
1
) with the light
bulb and override symbol displayed - if the override was to ON and not if it was to
OFF - (symbols can take 2-4 seconds to appear and disappear)
⇒
Button
–X->
again to cancel the override if necessary
To override channel P2 - DHW
⇒
Button
–X->
twice
2
will appear to the right of the time display (ie:6.30
2
) with the light
bulb and override symbol displayed if the override was to ON and not if it was to OFF
⇒
Button
–X->
again twice to cancel the override
Note:
1.
The
1
returns on the first press but both disappear after 2-4 seconds
2.
When overriding the timer to OFF there is a 2-4 second delay before the
1
and
2
and
light bulb disappear from the display
To override both channels P1 and P2 to ON
⇒
Press button
–X->
twice and the
2
appears with the light bulb and override symbol
⇒
Press button
–X->
again and the
1
appears
Both channels are now ON
To override both channels P1 and P2 to OFF
⇒
Press button once and the
1
disappears
⇒
Press button twice and the
2
disappears along with the light bulb and override symbol
Both channels are now OFF - The
1
returns on the first press but both disappear after 2-4
seconds
12. Programming
Errors
Each ON switching point is linked to the next in sequence OFF switching time therefore the follow-
ing combinations of ON/OFF switching can lead to errors preventing the timer working or creating
unexpected switching times - If in doubt re-set timer and program again
Switch ON time
Switch OFF time
ON time set
Next OFF time not set
No time set
Next switch OFF time set
Day block ie: M to F
Different day block ie: S to Su
On time set to eg: W - 08.00
Next OFF time set before ON time eg: W - 07.30
On time set to eg: Su - 09.00
OFF time set same eg: Su - 09.00
Содержание Avanta Plus 24s
Страница 94: ...30...
Страница 95: ...31...
Страница 97: ...2 AVANTA PLUS 28 Combi Gas Council No 47 673 02 39 Combi Gas Council No 47 673 04...
Страница 100: ...5...
Страница 104: ...9...
Страница 107: ...12 AVANTA PLUS 24 System Gas Council No 41 288 05...
Страница 110: ...15...
Страница 118: ...User guide Remeha Avanta Plus Remeha Avanta Plus 28c Remeha Avanta Plus 39c Remeha Avanta Plus 24s...
Страница 146: ...1 Issue No 1 Date 8 December 2005 Operating instructions for the built in Two Channel Digital electronic time clock...
Страница 149: ...4 6 Description of setting buttons and display M T W Th F S Su DAY HR MIN Set 5 Position of Timer in boiler when fitted...