8.3.3 Regulating the water temperature
The Remeha Avanta Plus is fitted with an electronic tempera-
ture regulator with flow and return temperature sensors. The
flow temperature can be set to between 20 and 85°C,
see
2.9.8 (factory setting
75°C). The boiler modulates it’s output up
and down to match the flow set point from internal or external
control. When the boiler is at it’s at minimum output and the
flow temperature still continues to rise, once the flow set point
is exceeded by 5°C the boiler will shut down on a controlled
stop (code
8
).
8.3.4 Low flow / water protection
The Remeha Avanta Plus has a low-water protection based on
temperature readings. By modulating down as soon as there
is a risk of an insufficient water flow, the boiler will keep work-
ing for as long as possible. An insufficient water flow, however
caused, - indicated by a flow/return
d
t
]
45°C or a rate of
rise in the flow temperature > 1°C/sec – will be sensed by
the
‘abc
®’
control which will shut the boiler down in a blocking
mode with the display showing (code
9
) for 10 minutes and
before re-starting.
If there is no water in the boiler or if the pump is not running, it
will go to lock out (code
é7
) and require manual re-set.
8.3.5 High Limit temperature protection
If the flow temperature exceeds 110°C the high limit tempe-
rature protection device switches off the boiler in a lock out
mode with the display showing (code
é
1
) This mode will
require a manual re-set.
When the fault is corrected, the boiler can be restarted by
pressing the
reset
-key on the control panel and holding for 3
seconds.
Содержание Avanta Plus 24s
Страница 94: ...30...
Страница 95: ...31...
Страница 97: ...2 AVANTA PLUS 28 Combi Gas Council No 47 673 02 39 Combi Gas Council No 47 673 04...
Страница 100: ...5...
Страница 104: ...9...
Страница 107: ...12 AVANTA PLUS 24 System Gas Council No 41 288 05...
Страница 110: ...15...
Страница 118: ...User guide Remeha Avanta Plus Remeha Avanta Plus 28c Remeha Avanta Plus 39c Remeha Avanta Plus 24s...
Страница 146: ...1 Issue No 1 Date 8 December 2005 Operating instructions for the built in Two Channel Digital electronic time clock...
Страница 149: ...4 6 Description of setting buttons and display M T W Th F S Su DAY HR MIN Set 5 Position of Timer in boiler when fitted...