22
Remeha Avanta Plus
7
ENABLING THE BOILER
LT.AL.W7H.000.211
LTALW7H000211a
1,5 ... 2 bar
•
Check the boiler water pressure. If the water pressure
is less than 1 bar, the system has to be topped up
with water,
see par.
5.1
.
LT.AL.W7H.000.223
LTALW7H000223a
R
•
Switch on the boiler at the fused spur unit; the boiler will
run the start-up program.
- A display test will briefly appear showing all segments of
the display.
f[ xx
software version;
p[ xx
parameter version;
- A venting cycle of 2 minutes now follows, the version
numbers will be displayed alternately;
- Next, the following will appear in the display;
[1
; boiler is ventilating;
[2
; boiler is igniting;
[4
; boiler is operating for DHW;
[7
; boiler pump is running after heating DHW;
[0
; boiler is stand-by.
LT.AL.W7H.000.212
LTALW7H000212a
•
Set the room thermostat to the desired room temperature.
The boiler will now automatically start operating.
See par.
3.2
for an explanation of the codes on the display.
LT.NL.W6H.000.079
R
LTNLW6H000079A
Error message
If the boiler does not start operating and an error message is
displayed, consult the error table in
par.
4.1
and, if necessary,
consult the installer.
Содержание Avanta Plus 24s
Страница 94: ...30...
Страница 95: ...31...
Страница 97: ...2 AVANTA PLUS 28 Combi Gas Council No 47 673 02 39 Combi Gas Council No 47 673 04...
Страница 100: ...5...
Страница 104: ...9...
Страница 107: ...12 AVANTA PLUS 24 System Gas Council No 41 288 05...
Страница 110: ...15...
Страница 118: ...User guide Remeha Avanta Plus Remeha Avanta Plus 28c Remeha Avanta Plus 39c Remeha Avanta Plus 24s...
Страница 146: ...1 Issue No 1 Date 8 December 2005 Operating instructions for the built in Two Channel Digital electronic time clock...
Страница 149: ...4 6 Description of setting buttons and display M T W Th F S Su DAY HR MIN Set 5 Position of Timer in boiler when fitted...