7. Initialising
Timer
On removal from box the display will appear as shown above and MUST be Initialised be-
fore it can be used in any of the modes including manual override using switch 7 to I
To initialise timer set with the day pointer under
M
1.
Set program switches 7 to
AUTO
and 8 to
RUN
2. Press
HR
and
MIN
buttons together for 3 seconds - display changes to
0:00
3.
Set current time - button
HR
for the hour and
MIN
for minutes
4.
Set current day - button
DAY
until pointer is under correct day (
M-Su
)
Note: if time is not set within 15 seconds the
:
flashes and timer starts from
0:00
(midnight)
5. Repeat 2 - 4
8.
Setting switching programs P1 - Heating
⇒
Set program switches 7 to
AUTO
and 8 to
P1
for Heating times - the display will
show factory default times with a
1
to the right of the time and
I
below it (ie:
6:30
1
I
)
with the bulb symbol confirming channel
P1
and first ON switching position
⇒
Set day or group of days using
DAY
button - use button to scroll between set
choices, individual days or groups of days to suit needs (
M
to
F
or
S
to
Su
etc)
⇒
Edit first on time required for that day or group of days using
HR
and
MIN
buttons
⇒
Button P to select first off time - again factory default time is displayed with a
1
to the
right of the time and
2
below it (ie:
8:30
1
2
) without the bulb symbol confirming channel
P1 and first OFF switching position
Repeat process for up to 8 pairs of ON/OFF switching times
NOTE :
1.
Odd numbers are ON and even numbers are OFF times - a “light bulb” symbol will
also appear during the ON time setting
2.
Any unused switching times should be checked and deleted to avoid them overriding
any of your set times - press buttons
–X->
and
P
together for 3-4 seconds, the dis-
play will change to 0.00 flashing confirming that the switching setting is deleted
9.
Setting switching programs P2 - Domestic Hot Water
⇒
Set program switches 7 to
AUTO
and 8 to
P2
for DHW times - the display will show
factory default times with a
2
to the right of the time and
I
below it (ie:
6:30
2
I
) with a
light bulb symbol confirming channel
P2
and first ON switching position
⇒
Repeat process described above for channel
P1
Set program switch back to
RUN
Timer will now operate the boiler in accordance with the switch times set
7
8
Содержание Avanta Plus 24s
Страница 94: ...30...
Страница 95: ...31...
Страница 97: ...2 AVANTA PLUS 28 Combi Gas Council No 47 673 02 39 Combi Gas Council No 47 673 04...
Страница 100: ...5...
Страница 104: ...9...
Страница 107: ...12 AVANTA PLUS 24 System Gas Council No 41 288 05...
Страница 110: ...15...
Страница 118: ...User guide Remeha Avanta Plus Remeha Avanta Plus 28c Remeha Avanta Plus 39c Remeha Avanta Plus 24s...
Страница 146: ...1 Issue No 1 Date 8 December 2005 Operating instructions for the built in Two Channel Digital electronic time clock...
Страница 149: ...4 6 Description of setting buttons and display M T W Th F S Su DAY HR MIN Set 5 Position of Timer in boiler when fitted...