38
Remeha Avanta Plus
R
R
m
Changing the factory settings could result in the boiler not
working properly.
LT.AL.W7H.000.047
The parameters can be changed from the stand-by status as
follows:
•
Press the
[enter]
-key
and briefly the
[reset]-
key
until
codes
c
and
0
appear alternately in the display.
•
Press the
[+]
-key
until access code
12
is displayed.
•
Press the
[enter]
-key until
p1
appears (codes
p
[
and
[
1
are displayed alternately);
•
This parameter can now be changed as follows;
•
Press the
[enter]
-key; the set value for the maximum flow
temperature now appears e.g.;
75
(75°C).
•
Press the
[+]
or
[-]-
key to change this value, for example to
65
(65°C).
•
Press
[enter]
-key to confirm the value; codes
p
[
and
[
1
are displayed alternately.
•
Press the
[+]
-key
to change
the next parameter, etc.
•
Press
[reset]
-key to return to the operating mode.
o
The boiler will automatically return to the normal operating
mode if no keys are pressed for 10 minutes.
2.9.9 Changing the maximum output (Hi) for CH operation
The maximum output for CH operation can be changed with
parameter
p 17
(maximum fan speed) and is set standard
to a speed of 3700, 4100 or 5000 rpm. See the speed-input
ratio figures.
This parameter can be changed from the stand-by status as
follows:
LT.AL.W7H.000.048
•
Press the
[enter]
-key
and briefly the
[reset]-
key
until
codes
c
and
0
appear alternately in the display.
•
Press the
[+]
-key
until access code
12
is displayed.
•
Press the
[enter]
-key until
p1
appears (codes
p
[
and
[
1
are displayed alternately);
•
Press the
[+]
-key
to go to parameter
17
.
•
Press the
[enter]
-key until
p17
appears (codes
p
[
and
17
are displayed alternately);
•
Press the
[+]
or
[-]-
key to change this value for Avanta
Plus
28c, for example to
46
(4600 rpm corresponds with 22
kW).
•
Press
[enter]
-key to confirm the value.
•
Press
[reset]
-key to return to the operating
mode.
Содержание Avanta Plus 24s
Страница 94: ...30...
Страница 95: ...31...
Страница 97: ...2 AVANTA PLUS 28 Combi Gas Council No 47 673 02 39 Combi Gas Council No 47 673 04...
Страница 100: ...5...
Страница 104: ...9...
Страница 107: ...12 AVANTA PLUS 24 System Gas Council No 41 288 05...
Страница 110: ...15...
Страница 118: ...User guide Remeha Avanta Plus Remeha Avanta Plus 28c Remeha Avanta Plus 39c Remeha Avanta Plus 24s...
Страница 146: ...1 Issue No 1 Date 8 December 2005 Operating instructions for the built in Two Channel Digital electronic time clock...
Страница 149: ...4 6 Description of setting buttons and display M T W Th F S Su DAY HR MIN Set 5 Position of Timer in boiler when fitted...