46
Remeha Avanta Plus
7
4
4x
3
1
2
3. Dismantling the front plate of the heat exchanger
LT.AL.W7H.000.060
•
Release the ignition transformer mounting plate and remove
it completely.
•
Disconnect the electrical connection on the gas block.
•
Release the union nut from the gas pipe on the outlet to the
gas block.
•
(Disconnect the 230 V fan plug; Avanta Plus 39c only)
•
Release the four nuts on the heat exchanger front plate
•
Carefully pull the front plate assembly c/w fan, gas block,
venturi pipe and burner unit away from the heat exchanger
by approx. 10 cm.
•
Disconnect the electrical plug on the back of the fan, so it
becomes accessible.
•
Remove the front plate assembly completely.
4. Maintenance to the burner
LT.AL.W7H.000.061
•
Carefully clean the burner with pressured air (do not keep
the nozzle to close to the surface).
•
Visual inspection of the burner for any damages or cracks
on the surface. If you see any damages, then replace the
burner.
Содержание Avanta Plus 24s
Страница 94: ...30...
Страница 95: ...31...
Страница 97: ...2 AVANTA PLUS 28 Combi Gas Council No 47 673 02 39 Combi Gas Council No 47 673 04...
Страница 100: ...5...
Страница 104: ...9...
Страница 107: ...12 AVANTA PLUS 24 System Gas Council No 41 288 05...
Страница 110: ...15...
Страница 118: ...User guide Remeha Avanta Plus Remeha Avanta Plus 28c Remeha Avanta Plus 39c Remeha Avanta Plus 24s...
Страница 146: ...1 Issue No 1 Date 8 December 2005 Operating instructions for the built in Two Channel Digital electronic time clock...
Страница 149: ...4 6 Description of setting buttons and display M T W Th F S Su DAY HR MIN Set 5 Position of Timer in boiler when fitted...