511026 Rev. 07-01-19
159
Event Code
Message Text and Description
Details and Solution
2074
The library startup failed due to a GPIO
error.
Reboot or power cycle system.
2075
The library startup failed due to an error
when trying to open the robotics serial
port.
Reboot or power cycle system.
2076
I2C bus signals invalid.
Remove all drive canisters of the affected chassis
and reboot the library. If the problem persists,
replace the chassis. If not, add one drive after the
other until the problem comes back. Replace the
last drive added before it failed again.
2077
Failed to store Calibration Data to
Chassis.
Reboot or power cycle system.
2078
Incompatible Robotics Assembly without
Encoder detected.
Replace Robotics Assembly with a compatible
model with Encoder or upgrade Firmware to a
version which supports Encoder-less control.
2079
Could not upgrade barcode reader
firmware.
Reboot the library and if the error persists replace
the robotics.
2080
Cartridge lost while inserting it into
slot/drive.
Check the source/destination element and ensure
that there are no obstructions in the pathway of the
robot.
2081
I2C port expander read write error.
Reboot the library and if the error persists replace
the chassis. Prior to replacing the chassis, ensure
you remove all of your tape cartridges. If magazines
need to be removed to get access to the tape
cartridges, first power down the device and then
manually release each magazine. Only one
magazine should ever be opened at a time.
2083
Drive Power Board is not compatible to
this Library and does not match to the
installed power supply.
Remove incompatible Drive Power Board. Only
install Drive Power Boards that are compatible with
the library.
2084
Lost connection to Module, possibly due
to abnormal network activity.
Ensure that all modules are powered on and have
the interconnect cable properly attached. If this
event is seen on multiple modules, ensure that the
network that the Base Module is connected to is not
experiencing broadcast storms or other abnormal
activity. Reboot or power cycle the system to re-
discover the modules.
2085
Communication failure to the Base
Module controller board I2C port
expander component.
Until this issue is resolved, the base module will not
be able to discover any attached expansion
modules. Reboot the library. If the error persists,
power off the library and reseat the base module
controller. If the error continues to persist, replace
the base module controller.