511026 Rev. 07-01-19
109
The
Library Status section provides the following information:
•
Idle
– The library robotic is ready to perform an action.
•
Moving
– The library robotic is moving a cartridge.
•
Scanning
– The library robotic is performing an inventory of cartridges.
•
Offline –
The library robotic has been taken off line by the library.
•
Robotic Location –
Displays the module where the robotic is currently located
•
Shipping Lock –
Indicates whether the robotic is unlocked or locked for shipment
•
Cartridge in Transport
– When applicable, displays the barcode label of the cartridge currently in the
robotic assembly.
•
Total Power On Time
– Total time that the Base Module has been powered on since it was
manufactured
•
Odometer
– Robotic assembly move count
The Module Status section provides the following information:
•
Base Controller Revision or Expansion Controller Revision
– Hardware revision of the controller
board currently installed in the module.
•
Drive Power Board Status
– Status of the drive power board (DC-DC converter) for the three half-
height drive slots in the module.
•
Power Supply Status –
Displays the status of power redundancy.
•
Lower/upper Power Supply –
Displays the presence status of the power supplies
6.19.2 Cartridge Inventory
To see the library’s current inventory information, navigate to
Status > Cartridge Inventory
.
There are 2 views available to see the inventory, Graphical View and List View.
6.19.2.1
List View
In the Inventory List View, you can see:
•
Module –
The module number
•
Slot # -
The slot number in the form <module> <slot>.
•
Label –
Barcode label.
•
Full –
X if a cartridge is using the element.
•
Gen –
LTO generation of the cartridge
•
Partition –
The partition number