Wireless Door Alarm System
51
114A3873.D rev. 7-2017
•
Low Battery 0001
The multiplexer monitors each transmitter for battery condition.
•
Transmitters begin to report a low battery condition to the multiplexer at
least one week before their batteries fail.
•
The numbers following the message are the transmitters’ registered
channel numbers.
•
The controller looks up the channel number in the cross-reference table.
•
If the channel is not assigned, the event reports as Unknown Low Battery
with a reference to the multiplexer and channel numbers.
•
If the channel is assigned, the event will report as Unit Low Battery with a
reference to the unit number.
•
The actual reporting of the event depends on the configuration of the
controller.
•
To get attention, the multiplexer sends this notification to the controller
every six hours until the problem is corrected.
•
See “Battery Replacement” on page 62 for more information.
•
Receiver On 0001
Indicates that the multiplexer is in contact with the receiver.
•
This event always shows a channel number of 1 and reportts every time the
multiplexer is powered on or when the receiver is connected after being
off.
•
It reports to the controller as
Data Comm. One - Controller 1
referenced to the multiplexer number.