Wireless Door Alarm System
Unit Address
The Unit Address is the address of the multiplexer on the RS485
communications line. This parameter must be set for the multiplexer
to operate error-free.
If an improper address is entered, the display will show an invalid
address message and repeat the prompt for the address. The
factory default for the address is 1.
Communications Rate
The Communications Rate is the baud rate used by the controller
to communicate to the multiplexer. Press the
*
key to step through
the available options.
NOTE: The controller can only communicate to remote devices
at 1,200 and 9,600 baud. The other available options are for
future use. The factory default setting is 9,600 baud.
Current Address: 005
Enter New Address:
PRESS # WHEN DONE
The address must be unique, make sure no other devices
on the network use the same address.
The valid address range is from 1 to 127 for a Falcon XT and
1 to 31, for a Falcon Base Unit. Do not use address 22 as it
is reserved by the controller.
Communications Rate:
9600 baud
Press
*
to Change,
PRESS # WHEN DONE